Special Class Of Service For A Blocked Extension - Siemens HiPath 1100 Programming Manual

Analog mf telephones
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Step by Step
Special Class of Service for a Blocked Exten-
sion
This allows you to switch a blocked extension (with an
electronic lock) to any class of service.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
0 9 6
Enter the extension number (e.g., 12/102).
Enter the Class of Service for the extension with the ac-
tivated lock:
0
= No Trunk Access (default setting for all exten-
= Outward-Restricted Trunk Access with Denied
1
= Outward-Restricted Trunk Access with Denied
2
= Outward-Restricted Trunk Access with Denied
3
= Outward-Restricted Trunk Access with Permis-
4
5
= Outward-Restricted Trunk Access with Permis-
6
= Outward-Restricted Trunk Access with Permis-
= Unrestricted Trunk Access (default for all lines)
7
Press this key.
#
Initial state for Programming Mode.
To assign a COS to additional lines, repeat the program-
ming steps described above.
sions)
List 1 (4 slots)
List 2(10 slots)
List 3 (35 slots)
sion List 1 (4 slots)
sion List 2 (10 slots)
sion List 3 (25 slots)
The system administrator is responsible for
maintaining the balance of the Classes of Ser-
vice used by an extension that is blocked or free.
This prevents an extension with a restricted ser-
vice from having free access when the lock is not
activated and then keep an unrestricted category
when the lock is activated.