Setup and Installation

Setup and Installation
This chapter provides basic instructions and describes procedures for set-
ting up the HiPath 1120 and HiPath 1150. Due to the size of the HiPath
1190 system and the many configuration options installation documenta-
tion must be kept by qualified technical personnel only.

Safety Recommendations

To ensure proper and reliable operation follow these guidelines when set-
ting up your system:
.
184
Install the system in a central location taking into account the length
and extension of cables.
The location chosen should satisfy the following environmental require-
ments:
- Internal environment with natural air flow of air
- Operation: 23°F to 113°F (-5°C to +45°C), from 5% to 95% RH
To avoid electrical hazards keep a safety lock on the main distributing
frame of the HiPath 1150.
Protect against flood, flammable materials, excessive dust, vibration
and mechanical stress.
Do not install the system where there is a risk of exposure to sunlight,
humidity, heating or cooling sources or proximity to electrical cabling.
Avoid placing the equipment near data transmission equipment, elec-
trical soldering devices, copy machines, PCs and other electrical equip-
ment that could cause electrical interference
Install a power outlet for the equipment at a distance of no more than
6.5 feet (2 meters).
Do not block the natural flow of air around the equipment.
Do not install inside closets
Note: For RSA - África do Sul version extension lines with a C/D in-
terface must be installed indoors only. Only regular extensions
(without a C/D interface) can be installed outdoors.
Warning: Only service and installation personnel should open the
PABX box and/or connect and handle trunk and extension lines.