Features and Options
External Analog Lines
Digital line (TME1)+ analog line / digital
line (S
)+ analog line
0
[1] Each system telephone (KS) that is connected occupies one analog telephone slot.
[2]
0 and TME1 modules cannot be used simultaneously.
S
On the HiPath 1150 and HiPath 1190 ADSL and TME1 modules can be used simultaneously.
[3] When the maximum capability for external lines is exceeded due to the installation of EB, S
the system disables a number of external analog lines, adjusting the capability as needed for each system. The
extensions slots, however, will continue to operate as usual.
Example 1: HiPath 1150
- Slot 0, MB 210,
- Slot 1, EB 210,
- Slot 3 TME1 - 30 digital lines
EB 210 external line will not work, but extensions will. Since the system allows for a maximum number of 32
lines we cannot have any additional analog line.
Example 2: HiPath 1150
- Slot 0, MB 210
- Slot 3 TME1 = 30 digital lines
In this case, there are 32 external lines at a maximum available on the system. This means there is no room
for an additional EB module with an external analog line.
30 CAS digital lines + 2 MB external analog lines = 32 external lines.
If an EB 200 was installed in Slot 1 or Slot 2 the module would not be operable, since it would exceed the
system's maximum capacity for external lines.
Example 3: HiPath 1150
- Slot 0, MB 210
- Slot 3 TME1 = 10 digital lines
WARNING: Deactivate digital line for the TME1 Module and program unused digital lines on the switch as un-
available.
Overall, there are 12 external lines on the system. This means there are 4 additional external lines available
before reaching the maximum capacity of 16 external lines for this combination.
An additional EB 400 could be used in Slot 1 or Slot 2.
If an EB 800 was installed on the switch, the entire module would be inoperable since it would exceed the
system's maximum capacity for external lines.
Considerations related to digital line on the HiPath 1150/1190
HiPath 1150
Maximum number of external lines allowed is 16 (S0 digital lines + external analog lines)
Configuration
MB + 1 EB 800
MB + 1 EB 800 + 1 EB 400 + 1 EB 200
MB + 1 S0-2
MB + 1 S0-2 + 1 EB 800 + 1 EB 200
MB + 1 S0-5
MB + 1 S0-5 + 1 EB 400
16
6
0/8
External analog line
10
16
2
12
2
6
16
32/16
or TME1 modules,
0
S0 Module digital line
0
0
4
4
10
10
40
45/44
Total
10
16
6
16
12
16