Step by Step
1
Enter the next extension number.
or
#
Press this key.
Initial state for Programming Mode.

Overflow extension

An Overflow Extension (Escape Extension) is config-
ured to answer calls only when the extension called is
not available.
Examples:
The extension called is activated for room monitor-
ing (Babyphone)
The extension that was programmed as the first at-
tendant is currently assigned as Door Opener
No extension is configured (all extensions were de-
leted using the code "42").
By default, the first extension of the system is config-
ured as the Overflow Extension for Busy signal or
Wrong Number.
Required: Programming Mode must be active (*95
31994).
1 3 2
Enter the code for programming.
...
Choose a list for Call Forwarding:
3
= No answer
1
2
= Busy
= Wrong number
3
Enter the extension number (e.g. 12 /102) to be added
to the list.
Initial state for Programming Mode.
The system has the capability for Automatic Flash
Detection.
The Overflow Extension is accessed using your
own internal number.
The Overflow Extension cannot be configured or
used for Fax.