Operation As A Satellite Pabx; External Line Connection - Siemens HiPath 1100 Programming Manual

Analog mf telephones
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Step by Step
1

Operation as a Satellite PABX

External Line Connection

This feature determines if an external analog line con-
nected to one of the HiPath 1100 systems is also con-
nected to a local carrier or another PABX.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
1 3 3
...
Enter the number for the group of external lines (e.g., 0,
890).
or
Enter the code for the type of connection:
2
= Connection to a local carrier (default)
1
= Connection to another PABX system
2
Press this key.
#
Initial state for Programming Mode.
When a group of external lines is configured as a
Satellite PBX, a false dial tone is not generated.
However, when LCR (code 225) or Emergency
Number (code 040) are present and configured,
a False Dial Tone is generated.
When a line is configured to be connected to a
Local Carrier, its default Flash duration is 240
ms. When it is configured as as Satellite PABX,
the default time is 100 ms.