User Manual of Thermometric Bi-spectrum Network Positioning system
capture.
 Add Original Data on Stream: Check the checkbox to add original data on
stream.
 Data Refresh Interval: Select the data refresh interval from 1s to 5s.
 Unit: Display temperature with Degree Celsius (°C)/Degree Fahrenheit
(°F)/Degree Kelvin (K).
 Temperature Range: Set the temperature range.
3. Clcik Save to save the settings .

6.7.2 Temperature Measurement and Alarm

Purpose:
This function is used for measuring the temperature of detected spot and the device
compares temperature of selected regions and alarms.
Steps:
1. Enter Configuration > Advanced Configuration > Temperature Measurement
and Alarm.
2. Adjust the image to the scene for temperature measurement with the PTZ
control panel. Save current scene as certain preset.
You can set the preset in live view interface before and call the preset in the
temperature measurement and alarm interface.
You can set/ call/ clear the preset in temperature measurement interface.
3. Set the alarm rule: Select a temperature measurement rule from the rule list and
configure the parameters.
 Name: You can customize the rule name.
 Type: Select point, line, or frame as rule type.
 Emissivity: Set the emissivity of your target. Note: The emissivity of each
object is different.
 Distance (m): The straight-line distance between the target and the device.
 Reflective Temperature: If there is any target with high emissivity in the scene,
check the checkbox and set the reflective temperature to correct the
temperature. If no such target exists, uncheck the checkbox.