User Manual of Thermometric Bi-spectrum Network Positioning system
10 seconds, Always Close or Always Open.
 PT Status: Set the azimuth angle display duration while panning and tilting as
2 seconds, 5 seconds, 10 seconds, Always Close or Always Open.
 Preset Status: Set the preset name display duration while calling the preset as
2 seconds, 5 seconds, 10 seconds, Always Close or Always Open.
Power-off Memory: The positioning system can resume its previous PTZ status or
actions after it restarted from a power-off. You can set the time point of which
the positioning system resumes its PTZ status. You can set it to resume the status
of 30 seconds, 60 seconds, 300 seconds or 600 seconds before power-off.
3. Click

5.2 Configuring PTZ Limits

Purpose:
The positioning system can be programmed to move within the configurable limits
(left/right, up/down).
Steps:
1. Enter the Limit Configuration interface:
Configuration > Advanced Configuration > PTZ > Limit
2. Click the checkbox of Enable Limit and choose the limit type as manual stops or
scan stops.
 Manual Stops:
© Hikvision
to save the settings.
Figure 5-2 Configure the PTZ Limit