User Manual of Thermometric Bi-spectrum Network Positioning system
Figure 6-46 Motion Detection Settings-Expert
(1) (Available for the optical channel only) Set the Day&Night switch mode, there
are OFF, Auto-Switch and Scheduled-Switch selectable. If the Day&Night
switch mode is enabled, you can configure the detection rule for the day and
night separately.
OFF: Disable the day and night switch.
Auto-Switch: Switch the day and night mode according to the illumination
automatically.
Scheduled-Switch: Switch to the day mode at 6:00 a.m., and switch to the
night mode at 18:00 p.m..
(2) Select Area No. to configure in the dropdown list.
(3) Set the values of sensitivity and proportion of object on area.
Sensitivity: The greater the value is, the easier the alarm will be triggered.
Proportion of Object on Area: When the size proportion of the moving object
exceeds the predefined value, the alarm will be triggered. The less the value is,
the easier the alarm will be triggered.
5. Set the Arming Schedule for Motion Detection.
(1) Click
© Hikvision
in Figure 6-47.
82