HIKVISION Positioning System User Manual page 99

Thermometric bi-spectrum network
Table of Contents

Advertisement

User Manual of Thermometric Bi-spectrum Network Positioning system
advanced configuration page. You can configure these parameters for different VCA
types on your demand.
Steps:
1. Enter the Advanced Configuration interface:
Configuration > VCA Configuration > Advanced Configuration
2. Adjust the Detection Parameters.
Detection Sensitivity: Range [0-4], the higher the sensitivity is, the easier the
target will be detected.
Background Update Rate: Range [0-4], if a detected target remains in the
monitoring scene for a certain time, the system will count the target as the
background automatically. The greater the value is, the faster the target will be
counted as the background.
Minimum Target Size: Range [0-4], The system will filter out the object smaller
than the minimum target size.
Displacement Constraint for Target Generation: Range [0-4], the higher the
value is, the slower the target is generated, and the higher accuracy the analysis
will get.
Light Change Suppression: Check the checkbox to suppress the impact caused
by the illumination change.
3. Adjust the Tracking Parameters.
Post-Tracking: Range [2-600], you can configure the tracking duration after the
target is still.
Force Tracking: Check the checkbox to enable the function to prevent the object
to be blocked. After the function being enabled, the positioning system will
continue locating and tracking the blocked target.
Restore Default: Click
Restart VCA: Click
© Hikvision
Figure 7-3
Advanced Configuration
to restore the parameters to the default.
to restart the VCA function.
98