7. Click

6.6.3 Configuring Alarm Input

Steps:
1. Enter the Alarm Input Settings interface:
Configuration > Advanced Configuration> Events > Alarm Input:
2. Choose the alarm input No. and the Alarm Type. The alarm type can be NO
(Normally Open) and NC (Normally Closed).
3. Edit the name in
name for the alarm input (optional).
4. Click
in Section 6.6.1 Configuring Motion Detection.
5. Check the checkbox to select the linkage method taken for the alarm input. Refer
to Step 3 in Section 6.6.1 Configuring Motion Detection.
6. You can also choose the PTZ linking for the alarm input. Check the relative
checkbox and select the No. to enable Preset Calling, Patrol Calling or Pattern
Calling.
7. You can copy your settings to other alarm inputs.
© Hikvision
to save the settings.
Figure 6-51 Alarm Input Settings
to set the arming schedule for the alarm input. Refer to Step 2