Danfoss VLT AutomationDrive FC 300 Design Manual page 75

90–1200 kw
Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

Selection
FC 302
High/Normal load*
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [HP]
Typical shaft output at 690 V [kW]
Enclosure IP21, IP54 without/with options
cabinet
Output current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous KVA (at 550 V) [KVA]
Continuous KVA (at 575 V) [KVA]
Continuous KVA (at 690 V) [KVA]
Maximum input current
Continuous (at 550 V) [A]
Continuous (at 575 V) [A]
Continuous (at 690 V) [A]
2
Max. cable size, motor [mm
(AWG)
Max. cable size, line power F1 [mm
Max. cable size, line power F3 [mm
Max. cable size, load sharing [mm
2
Max. cable size, brake [mm
(AWG)
2)
Max. external electrical fuses [A]
Estimated power loss at 600 V [W]
Estimated power loss at 690 V [W]
F3/F4 Max added losses CB or disconnect &
contactor
Max panel options losses
Weight, enclosure IP21, IP54 [kg]
Weight, rectifier module [kg]
Weight, inverter module [kg]
Efficiency
4)
Output frequency
Heatsink overtemp. trip
Power card ambient trip
* High overload=160% torque during 60 s, Normal overload=110% torque during 60 s.
Table 4.10 Technical Specifications, F1/F3 frames, 525–690 V Line Power Supply 3x525–690 V AC
1) American Wire Gauge.
2) For fuse ratings, see chapter 7.2.1 Fuses.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the adjustable frequency drive.
If the switching frequency is raised from nominal, the power losses rise significantly. LCP and typical control card power consumptions are
included. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B
each add only 4 W.
4) Measured using 16.5 ft. [5 m] shielded motor cables at rated load and rated frequency.
MG34S222
Design Guide
P630
HO
500
650
630
F1/ F3
659
989
630
945
628
627
753
642
613
613
1)
]
2
1)
(AWG)
]
2
1)
(AWG)
]
2
(AWG)
1)
]
1)
]
3) 4)
8075
3) 4)
8388
342
102
102
203 °F [95 °C]
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
P710
NO
HO
NO
560
560
670
750
750
950
710
710
800
F1/ F3
763
763
889
839
1145
978
730
730
850
803
1095
935
727
727
847
727
727
847
872
872
1016
743
743
866
711
711
828
711
711
828
8x150 (8x300 mcm)
8x240 (8x500 mcm)
8x456 (8x900 mcm)
4x120 (4x250 mcm)
4x185 (4x350 mcm)
1600
9500
9165
10872
9863
9537
11304
427
419
532
400
1017/1318
102
102
0.98
0–500 Hz
221 °F [105 °C]
185 °F [85 °C]
± 15% (tolerance relates to variety in voltage and cable conditions.) These
P800
HO
NO
670
750
950
1050
800
900
F1/ F3
4
889
988
1334
1087
850
945
1275
1040
847
941
847
941
1016
1129
866
962
828
920
828
920
10860
12316
11291
12798
519
615
102
136
203 °F [95 °C]
73
4

Advertisement

Table of Contents
loading

Table of Contents