Selection
FC 302
High/Normal load *
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [HP]
Typical shaft output at 500 V [kW]
Enclosure IP21, IP54 without/with
options cabinet
4
4
Output current
Continuous (at 400 V) [A]
Intermittent (60 s overload)
(at 400 V) [A]
Continuous (at 460/500 V) [A]
Intermittent (60 s overload)
(at 460/500 V) [A]
Continuous KVA (at 400 V) [KVA]
Continuous KVA (at 460 V) [KVA]
Continuous KVA (at 500 V) [KVA]
Maximum input current
Continuous (at 400 V) [A]
Continuous (at 460/500 V) [A]
Max. cable size, motor [mm
Max. cable size, line power
2
1)
[mm
(AWG)
Max. cable size, brake [mm
Max. external electrical fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
F9/F11/F13 max. added losses A1 RFI,
CB or disconnect, & contactor
F9/F11/F13
Max. panel options losses
Weight, enclosure IP21, IP54 [kg]
Weight, rectifier module [kg]
Weight, inverter module [kg]
4)
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
* High overload=160% torque during 60 s, Normal overload=110% torque during 60 s.
Table 4.5 Technical Specifications, F10-F13 frames, 380–500 V Line Power Supply 6x380–500 V AC, 12-Pulse
1) American Wire Gauge.
2) For fuse ratings, see chapter 7.2.1 Fuses.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the adjustable frequency drive.
If the switching frequency is raised from nominal, the power losses rise significantly. LCP and typical control card power consumptions are
included. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B
each add only 4 W.
4) Measured using 16.5 ft. [5 m] shielded motor cables at rated load and rated frequency.
68
P450
HO
450
600
530
F10/F11
800
1200
730
1095
554
582
632
779
711
2
1)
(AWG)
]
]
2
(AWG)
1)
]
2)
3) 4)
9492
3) 4)
8730
893
102
102
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
Design Guide
P500
P560
NO
HO
NO
HO
500
500
560
560
650
650
750
750
560
560
630
630
F10/F11
F10/F11
880
880
990
990
968
1320
1089
1485
780
780
890
890
858
1170
979
1335
610
610
686
686
621
621
709
709
675
675
771
771
857
857
964
964
759
759
867
867
8x150 (8x300 mcm)
6x120 (6x250 mcm)
4x185 (4x350 mcm)
900
10647
10631
12338 11263 13201 13172 15436 14967 18084 16392 20358
9414
9398
11006 10063 12353 12332 14041 13819 17137 15577 17752
963
951
1054
978
1017/ 1319
102
102
102
102
± 15% (tolerance relates to variety in voltage and cable conditions.) These
P630
P710
NO
HO
NO
HO
630
630
710
710
900
900
1000
1000
710
710
800
800
F10/F11
F12/F13
1120
1120
1260
1260
1232
1680
1386
1890
1050
1050
1160
1160
1155
1575
1276
1740
776
776
873
873
837
837
924
924
909
909
1005
1005
1090
1090
1227
1227
1022
1022
1129
1129
12x150 (12x300 mcm)
6x185 (6x350 mcm)
1500
1093
1092
1230
2067
400
102
136
136
102
0.98
0–590 Hz
203 °F [95 °C]
185 °F [85 °C]
P800
NO
HO
NO
800
800
1000
1200
1200
1350
1000
1000
1100
F12/F13
1460
1460
1720
1606
2190
1892
1380
1380
1530
1518
2070
1683
1012
1012
1192
1100
1100
1219
1195
1195
1325
1422
1422
1675
1344
1344
1490
2280
2236
2541
1261/ 1562
136
102
MG34S222