Commissioning

4.1

Introduction

You can operate the Vision Sensor SIMATIC VS 130-2/VS 130-2vcr interactively or
controlled by signals:
In this chapter, you will learn about interactive operation using the operator
control and display field of the evaluation unit.
The section Process interfacing explains the options open to you for signal-
controlled operation.
Note
The setup support for VS 130-2/VS 130-2vcr is described in detail in the Online
Help for Setup Support.
4.2

Turning on the Device

Turn on the power on the processing unit. The texts "Booting... SIMATIC V ..." and
then "Firmware Version V..." with the current firmware version appear on the
display.
The VS 130-2 or VS 130-2vcr then runs the following tests:
Test of the sensor head
Test of the stored settings and code data
If applicable, check whether data can be exchanged from and to PROFIBUS
(this check is made if you have selected "DP" for one or more of the following
signal paths: Output of the result string, feeding the trigger signal to the
processing unit, signal path for DISA, SEL0, SEL1, SEL2, SEL3, TRN, RES,
IN_OP, TRD, RDY, READ, MATCH, N_OK).
Test of the Ethernet connection
If applicable, check for the connection to PROFINET and to Ethernet RS-232
converter or TCP server and to the PC/PG on which diagnostic information will
be stored (over TCP/IP)
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
4-1