4
Commissioning
4.1
Introduction
You can operate the Vision Sensor SIMATIC VS 130-2/VS 130-2vcr interactively or
controlled by signals:
•
In this chapter, you will learn about interactive operation using the operator
control and display field of the evaluation unit.
•
The section Process interfacing explains the options open to you for signal-
controlled operation.
Note
The setup support for VS 130-2/VS 130-2vcr is described in detail in the Online
Help for Setup Support.
4.2
Turning on the Device
Turn on the power on the processing unit. The texts "Booting... SIMATIC V ..." and
then "Firmware Version V..." with the current firmware version appear on the
display.
The VS 130-2 or VS 130-2vcr then runs the following tests:
•
Test of the sensor head
•
Test of the stored settings and code data
•
If applicable, check whether data can be exchanged from and to PROFIBUS
(this check is made if you have selected "DP" for one or more of the following
signal paths: Output of the result string, feeding the trigger signal to the
processing unit, signal path for DISA, SEL0, SEL1, SEL2, SEL3, TRN, RES,
IN_OP, TRD, RDY, READ, MATCH, N_OK).
•
Test of the Ethernet connection
•
If applicable, check for the connection to PROFINET and to Ethernet RS-232
converter or TCP server and to the PC/PG on which diagnostic information will
be stored (over TCP/IP)
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
4-1