Process Interface
6.4

Control Via the "DI/DO" I/O Interface

6.4.1

Control Signals

You will find the pin assignment of the "DI/DO" I/O interface in Port pin Assignment
of the Processing Unit.
Input signals
Name
DISA
SEL0
SEL1
SEL2
SEL3
TRN
TRG
RES
Note
The SEL0, SEL1, SEL2, SEL3, TRN and RES signals only take effect when
DISA=1.
Output signals
Name
IN_OP
TRD
RDY
READ
MATCH Evaluation result: Code matches learned code
N_OK
6-6
Function
Disable: Disable manual control panel input, code selection and train via digital
I/O, error acknowledgment, start of the processing unit
Select 0: Code selection bit 0
Select 1: Code selection bit 1 (if TRN=0) / train code (if TRN=1)
Select 2: Code selection bit 2
Select 3: Code selection bit 3
Train: Train new code
Trigger : An evaluation is started on the positive-going edge
Reset: Reset error
Function
In operation:
0 = error message is displayed.
1 = SIMATIC VS 130-2/VS 130-2vcr functional, no errors
Trained:
In Run:
0 = selected code has not been trained
1 = selected code has been trained
In Training (TRN=1):
0 = training active
1 = acknowledgment signal (RDY=0)
Ready:
0 = Device startup or SIMATIC VS 130-2/VS 130-2vcr in
Stop
1 = SIMATIC VS130-2/VS 130-2vcr in run
Evaluation result: Code was localized and decoded
Code was not legible.
LEDs
Group error
TRAINED
READY
READ
MATCH
N_OK
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
SF on
SF off