Mode button
Current status of the
Vision Sensor
RUN
Adjust
STOP
Train
Error
"Trg" trigger button
This button exists only with the VS 130-2vcr. It is enabled only when the
processing unit is in RUN.
If you click on this button, you simulate an external trigger signal.
Code selection
Using the "<" and ">" buttons, select a trained code with the settings you want to
use for the image processing.
Code selection is enabled only in the adjustment mode.
Text display row
Current status of the
Vision Sensor
RUN
Adjust
STOP
Train
Error
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
Label of the Mode
Meaning
button
-> Adjust
Changes to the adjustment mode
-> Run
Changes to the processing mode
-> Adjust
Changes to the adjustment mode
-> Adjust
Changes to the adjustment mode
Acknowledge error
Acknowledges the error and exits the error
status
Content of the text display row
"Run:" + result string or "ReadErr (Nothing found)"
"Adjust: live" or "Adjust: read"
"Stop"
"Stop"
"Error:" + Error number
Operator Input
5-51