Permitted values for the COMMAND parameter
Value
Meaning
(W#16#...)
0000
Abort current job or no job
0001
Change code
0002
Train Code
0003
Output number of the code currently selected on the VS 130-2
0004
Output current mode of the VS 130-2.
0005
Reset DISA control signal
0081
Output the result string that may have been modified
0082
Output absolute quality characteristics
0083
Output absolute quality characteristics and result string
0084
Output quality characteristics as grades
0085
Output quality characteristics as grades and output result string
0086
Output quality characteristics as grades and absolute
0087
Output quality characteristics as grades and absolute and output result string
0088
Output code position
0089
Output code position and result string
008A
Output code position and output absolute quality characteristics
008B
Output code position and output absolute quality characteristics and output result string
008C
Output code position and output quality characteristics as grades
008D
Output code position and output quality characteristics as grades and output result
string
008E
Output code position and output quality characteristics as grades and absolute
008F
Output code position and output quality characteristics as grades and grades and
output result string