Operator Input
5.3.9

Maintain

Maintain code(s)
In this group box, you can deleted trained codes by selecting the relevant code
number from the drop-down list box and clicking on "Delete".
When you click the "Reset" button next to "Factory settings:" you reset all
parameters to their default values. The trained codes are also deleted.
Maintain processing unit
The "Save/Restore" button opens a Web page where you can save trained codes
and parameter assignments or load them on the processing unit again.
Note
When you load a code on the processing unit, the parameters saved with the code
are also loaded and therefore valid.
The "Firmware update" button opens a Web page where you can update the
firmware.
Note
If you control the VS 130-2/VS 130-2vcr from an automation system, make sure
that the DISA bit is not set during the firmware update. This prevents a
programmable controller from changing the processing unit to RUN.
5.3.10

Stop

When you call this dialog, you change the processing unit to STOP mode.
5-48
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01