Product Overview
Connecting the lamp multiplexer
You connect to the processing unit as follows: Connect a lighting cable
(6GF9 002-8CE) to the LAMP socket of the processing unit and to the input socket
LIN. of the lamp multiplexer.
Connect each of the maximum four lamps to the lamp multiplexer over a lighting
cable. Lamp 1 is assigned to socket L1, lamp 2 to socket L2 etc.
Connect the socket connector "DI/DO" of the processing unit to the left-hand plug
connector "DI/DO" of the lamp multiplexer with the supplied special cable. You can
connect a digital communication cable (6GF9 002-8CB) to the right-hand plug
connector "DI/DO". Please remember that you must not then use the MATCH and
NOK signals. These are used to select a lamp.
Note
If you connect the lamp multiplexer with connected lamps to a
VS 130-2/VS 130-2vcr while this is operating, this can lead to the processing unit
resetting itself in some situations.
Installing the lamp multiplexer
You have the following installation options:
Wall-mounting using the two holes at the upper end of the lamp multiplexer
Installation on a standard rail: In this case, screw the supplied rail adapter to
the back of the lamp multiplexer.
1-10
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01