Siemens SIMATIC Vision Sensor VS 130-2 Manual page 120

Hide thumbs Also See for SIMATIC Vision Sensor VS 130-2:
Table of Contents

Advertisement

Process Interface
Parameter
Declaration Data type Address
DONE
OUTPUT
Error
OUTPUT
ERRCODE
OUTPUT
STATE
OUTPUT
CODE_OUT OUTPUT
LENGTH
OUTPUT
6-22
(instance DB)
BOOL
22.1
BOOL
22.2
DWORD
24.0
WORD
28.0
BYTE
30.0
WORD
32.0
Default
Description
setting
FALSE
DONE=TRUE: Job completed
without error.
This means that the transfer
between processing unit and FB
(CPU) was successfully
completed error-free for read
jobs, (COMMAND =
W#16#0081 to 008F). In order
to find out if the DMC evaluation
was successful, you have to
evaluate the bits READ (Bit 3),
MATCH (Bit 4) and N_OK (Bit 5)
in the status byte of the
processing unit.
FALSE
ERROR=TRUE: An error has
occurred.
DW#16#
Error information:
00000000
DW#16#0000 0000:
No error
DW#16#0000 wxyz:
Warning
DW#16#0001 wxyz:
FB-internal error
DW#16#0002 wxyz:
Processing unit error
(refer to the error information
table at the end of this section)
W#16# 0000
Mode of the VS 130-2:
W#16#0000: Mode not up
to date
W#16#0001:
RUN (processing mode
with output of the result
string), in other words, bits
IN_OP and RDY are set in
the status byte.
W#16#0002:
STOP (incl. training and
adjust mode), in other
words, bit IN_OP is set in
the status byte, bit RDY,
however, is not.
W#16#0003:
ERROR, in other words, bit
IN_OP is not set in the
status byte
B#16#00
No. of the code currently set on
the VS 130-2
W#16# 0000
Length of the result string in
bytes
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr