Processing unit
Digital outputs for 24 V d.c.
DP interface
Ethernet interface
Limit data for evaluation of parts with data matrix code and Vericode
Permitted part rates
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
•
6; max. load 0.5 A each, however in total a maximum of 1.5 A
(15-pin D-sub female for inputs/outputs)
•
Cable length: 10 m (15 x 0.14 mm
9-pin D-sub socket; programmable;
•
Isolated: Data lines A, B; control lines RTS; 5-V power supply
(max. 90 mA)
•
Grounded Shield of the DP12 connecting cable; RS 485; floating
•
Non-floating 24 V/150 mA
8-pin RJ-45 jack, 10/100 Mbps
Depends on the dot size and code dimensions, however maximum 20/s
Appendix
2
)
8-17