No. Description
10
The trained code cannot be
processed with the match
settings (for example
ID/separator not found)
11
The code found during training
does not comply with the ECC
200 standard.
12
Error in PROFIBUS DP
communication.
13
Connection error in
communication over a TCP
connection or when using an
Ethernet RS-232 converter:
There is no TCP connection or
the data transfer cannot be
completed within the set time
limit.
14
Error in communication over the
archiving connection: There is no
TCP connection, the server does
not respond within the set time
limit or violates the archiving
protocol.
15
The IR lighting unit is
overloaded.
Below you will see the maximum
trigger frequency fT for the
selected shutter speeds TB:
Note: Trigger frequencies
> 33 Hz are not practicable.
16
You are attempting to train code
number 15 over digital I/O or
PROFIBUS DP or PROFINET
IO. This is, however, are
reserved for automatic learning.
18
An error occurred in PROFINET
I/O communication
19
An error occurred when saving
to the read-only memory.
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01
TB = 500 µs: fT = 60 Hz
TB = 1000 µs: fT = 40 Hz
TB = 2000 µs: fT = 20 Hz
TB = 3000 µs: fT = 13 Hz
TB = 4000 µs: fT = 10 Hz
TB = 5000 µs: fT = 8 Hz
TB = 6000 µs: fT = 7 Hz
TB = 7000 µs: fT = 6 Hz
TB = 8000 µs: fT = 5 Hz
TB = 9000 µs: fT = 4.5 Hz
TB = 10000 µs: fT = 4 Hz
Possible Remedies
Adapt the match settings, or train a suitable code.
Use a code that complies with the standard.
Make sure that the parameters for communication
over PROFIBUS DP and the communication
partners are correctly configured and active. Check
the connection to the DP master.
Make sure that the connected TCP server or
Ethernet RS-232 converter is correctly configured
and operational.
Depending on the connected Ethernet RS-232
converter, it can take up to 20 s before changes to
the RS-232 settings or parameter changes for the
trigger source or the output of the result string to
"TCP/RS232" take effect. During this time, the first
trigger of a processing cycle should not occur nor
should that be a change to RUN.
Check the connection to the server.
Make sure that the data is processed by the server
in an adequately short time and that the protocol is
maintained.
Reduce the trigger frequency or reduce the shutter
speed.
Select a code number between 1 and 14.
Make sure that the parameters for communication
over PROFINET I/O and the communication
partners are correctly configured and active. Check
the connection to the I/O controller.
Contact Customer Support if this error occurs
often.
Operator Input
5-53