Appendix
Ambient climatic conditions for operation
Environmental Conditions
Temperature
Temperature change
Relative atmospheric humidity Max. 95 % at +25 °C
Atmospheric pressure
Contaminant concentration
Note
The mechanical and climatic environmental conditions for operation specified
above apply only to the sensor heads with order numbers 6GF2 002-8DA01,
6GF2 002-8EA01 and 6GF2 002-8FA01.
For the sensor heads with order numbers 6GF2 002-8CB and 6GF2 002-8GB, the
mechanical and climatic environmental conditions depend on the lens used.
Circuits with rated voltage Uin between circuits
and to ground
0 V < Ue ≤ 50 V
50 V < Uin ≤ 100 V
100 V < Ue ≤ 150 V
150 V < Uin ≤ 300 V
8-20
Permitted Range
0 to +50 °C
Max. 10 °C/h
1080 to 795 hPa (corresponds to a
height of
-1000 to 2000 m)
•
SO2: < 0.5 ppm;
RH < 60 %, no condensation
•
H2S: < 0.1 ppm;
RH < 60 %, no condensation
Test voltages to IEC 61131-2
Test voltage
350 V
700 V
1300 V
2200 V
Comments
No condensation, corresponds to
relative humidity degree 2 to IEC
61131-2
•
Test: 10 ppm; 4 days
•
Test: 1 ppm; 4 days
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01