Diagnostics
No.
Signal
Bit-No. as of
Diagnostic
byte 0 (DP)
13
No ECC 200
12
code
14
PROFIBUS
13
DP Error
15
TCP/RS232
14
Communic.
16
ARCH/MMI
14
Communic.
7-4
Value
Description
(PROFINET)
W#16#500C
The code found during training
does not comply with the ECC
200 standard.
-
Error in PROFIBUS DP
communication.
W#16#500E
Connection error in
communication over a TCP
connection or when using an
Ethernet RS-232 converter:
There is no TCP connection or
the data transfer cannot be
completed within the set time
limit.
W#16#500E
Error in communication over
the archiving connection:
There is no TCP connection,
the server does not respond
within the set time limit or
violates the archiving protocol.
Possible
Remedies
Use a code that
complies with the
standard.
Make sure that the
parameters for
communication
over PROFIBUS
DP and the
communication
partners are
correctly
configured and
active. Check the
connection to the
DP master.
Make sure that the
connected TCP
server or Ethernet
RS-232 converter
is correctly
configured and
operational.
Depending on the
connected
Ethernet RS-232
converter, it can
take up to 20 s
before changes to
the RS-232
settings or
parameter
changes for the
trigger source or
the output of the
result string to
"TCP/RS232" take
effect. During this
time, the first
trigger of a
processing cycle
should not occur
nor should that be
a change to RUN.
Check the
connection to the
server.
Make sure that the
data is processed
by the server in an
adequately short
time and that the
protocol is
maintained.