Process Interface
Step
1
2
3
4
5
Note
If the selected code has not been trained, TRD and RDY retain the value 0.
6-8
Input
Output
DISA=1
TRN=0
TRG=0
RES=0
SEL0=1
SEL1=1
SEL2=0
SEL3=1
TRD=0
RDY=0
TRD=1
RDY=0
TRD=1
RDY=1
Description
Prepare code selection
DISA must have the value 1 for this. No edge
change is required, however.
Select code (based on example of code 11)
The code changeover is started
The code selection is confirmed after 150 ms.
Code 11 is selected.
The code changeover is completed after a time of
approximately 150 ms to 15 s.