Diagnostics
No. Signal
Description
11 TCP/RS232
In the self-test no connection to the
Esc: Skip
configured Ethernet RS-232 converter or.
PC/PG with TCP server can be
established (yet).
12 PROFIBUS
During the self-test it is still not possible
Esc:Skip
to start communication over PROFIBUS
DP.
13 Factory
The defaults for all parameters are used,
Settings used.
no codes have been trained. After the
self-test, the processing unit changes
immediately to the Adjust mode.
14 Code nn
During training, the system is waiting for
Training...
a trigger, or the triggered image is
currently being processed.
15 String=DP
The string output can only be configured
needs
for PROFIBUS DP when Control is also
Control=DP
configured for PROFINET I/O and/or
Control cannot be changed from
PROFINET I/O when String is configured
for PROFINET I/O.
The setting will not be adopted.
16 PROFINET
During the self-test it is still not possible
Esc:Skip
to start communication over PROFINET.
17 This will cause
IP mode is changed to PNIO or it is in
a restart.
PNIO and should retain another value.
The change comes into effect only after
a restart of the processing unit.
Confirmation with "OK" leads to a restart.
If you press "ESC", the change is not
applied and no restart occurs.
18 Invalid
You have entered an illegal value in a
Netmask
subnet mask under Ports > Ethernet. The
value will not be used.
19 Sensortype
You have connected a sensor with a
changed.
resolution that does not match that of the
Ok
previously connected sensor.
7-8
Possible Remedies
If the message does not disappear
automatically after a few seconds, check
the connection to the Ethernet RS-232
server or PC/PG with TCP server.
With ESC, you can skip connection
establishment (or it continues in the
background).
If the message does not disappear
automatically after a few seconds, check
the connection to the DP master.
With ESC, you can skip connection
establishment (or it continues in the
background).
Configure the Control parameter for
PNIO.
This message has its origins in the
changeover of the IP address during
reconfiguration. The message exists until
the changeover procedure has ended.
If the message does not disappear
automatically after a few seconds, check
the connection to the I/O controller.
With ESC, you can skip connection
establishment (or it continues in the
background).
The subnet mask must have the
following structure: 255.255.xxx.yyy
In binary terms, xxx.yyy must be made
up of ones without a gap seen from the
left and of zeros without a gap seen from
the right.
Note also: yyy <= 254
Confirming with OK leads to the following
warning.
Vision Sensor SIMATIC VS 130-2/VS 130-2vcr
A5E00475759-01