At^smonc Cell Monitoring - Siemens Brodersen MC55 AT Command Manual

At command manual
Table of Contents

Advertisement

8.6

AT^SMONC Cell Monitoring

The
execute command delivers cell information containing 9 values from a maximum of 7 base sta-
AT^SMONC
tions. The first base station is the serving cell.
Syntax
Test Command
AT^SMONC=?
Response(s)
OK
ERROR
+CME ERROR
Exec Command
AT^SMONC
Response(s)
,
^SMONC:
<MCC>
<MNC>
1
,
,
<MNC>
<LAC>
<cell>
2
2
OK
ERROR
+CME ERROR
Reference(s)
SIEMENS, 3GPP TS 05.08
Parameter Description
(num)
<MCC>
Mobile country code
3 digits, e.g. 232
000
(num)
<MNC>
Mobile network code
2 digits or 3 digits, e.g. 07 or 003
000
(num)
<LAC>
Location area code
4 hexadecimal digits, e.g. 4EED
0000
(num)
<cell>
Cell identifier
4 hexadecimal digits, e.g. 4EAF
0000
MC55_ATC_V04.00
Confidential / Released
,
,
,
<LAC>
<cell>
<BSIC>
1
1
1
,
,
,
<BSIC>
<chann>
<RSSI>
2
2
2
Not decoded
Not decoded
Not decoded
Not decoded
Page 172 of 475
,
,
<chann>
<RSSI>
1
1
,
,
, ...
<C1>
<C2>
2
2
2
PIN
ASC0 ASC1
MUX1
%
%
%
%
,
,
,
<C1>
<C2>
<MCC>
1
1
1
MUX2
MUX3 Charge
%
%
!
!
,
2
Last
!