When, for example, an SMS is being received and indicated by an unsolicited result code (URC), the ME
wakes up to full operation.
+CMTI: "SM",5
After this, you may want to verify the operating status:
AT+CFUN?
+CFUN: 1
EXAMPLE 3
To stop CYCLIC SLEEP mode and return to full functionality:
AT+CFUN?
+CFUN: 5
OK
AT+CFUN=1
OK
Remember that this approach is not applicable to the NON-CYCLIC SLEEP mode (since the serial interface
is disabled). The NON-CYCLIC SLEEP mode ends with the first wake-up event.
EXAMPLE 4
To reset and restart the ME:
AT+CFUN=1,1
OK
^SYSSTART
2.8.1
Wake up the ME from SLEEP mode
A wake-up event is any event that causes the ME to draw more current. Depending on the selected mode, the
wake-up event either switches the SLEEP mode off and takes the ME back to full functionality AT+CFUN=1, or
activates the ME temporarily without terminating the selected SLEEP mode.
Definitions of the state transitions described in Table 2.3:
•
Quit: ME exits SLEEP mode.
•
Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time
after the last character was sent or received on the serial interface.
•
No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.
Table 2.3:
Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes
Event
Ignition line
/RTS0 or /RTS1 activation Quit
Unsolicited Result Code
(URC)
Incoming voice or data
call
MC55_ATC_V04.00
Confidential / Released
Note that the URC used in this example will appear only, if
AT+CNMI=1,1 was configured before.
Indicates that ME has entered full functionality mode.
or alternatively, AT+CFUN=0,1 or 5,1 or 6,1 or 7,1 or 8,1 or 9,1
The ^SYSSTART URC confirms that the ME has been rebooted. Note
that ^SYSSTART appears only if
mode, it is recommended to wait 3 to 5 seconds before entering the first
AT command. Remember to enter the SIM PIN after restart.
Selected mode:
<fun>=0
No effect
Quit
Quit
Page 40 of 475
AT+IPR
Selected mode:
<fun>=5 or 6
No effect
No effect (RTS is only
used for flow control)
Quit
Quit
≠ 0. If the ME is in autobaud
Selected mode:
<fun>=7 or 8 or 9
No effect
Mode 7 and 8: No effect
(RTS is only used for flow
control)
Mode 9: Temporary
Temporary
Temporary