AT+ILRR Set TE-TA local rate reporting

The command
AT+ILRR
to the TE while a connection is being set up. The result code indicates the local rate. It is issued before the final
result code of the connection, e.g. CONNECT, is transmitted to the TE.
Syntax
Test Command
AT+ILRR=?
Response(s)
+ILRR: (list of supported <value>s)
OK
Read Command
AT+ILRR?
Response(s)
+ILRR:
<value>
OK
Write Command
AT+ILRR=<value>
Response(s)
OK
ERROR
+CME ERROR
Reference(s)
V.250
Intermediate Result Code
+ILRR:
<rate>
Indicates local port rate setting upon connection setup.
Parameter Description
(num)(&W)(&V)
<value>
(&F)
0
1
(num)
<rate>
Port rate setting upon connection setup (bps)
0
300
600
1200
2400
4800
9600
14400
MC55_ATC_V04.00
Confidential / Released
controls whether or not the intermediate result code "+ILRR" is transmitted from the TA
Disables reporting of local port rate
Enables reporting of local port rate
Autobauding (see Section 4.7.1, Autobauding). Not supported on ASC1.