Siemens Brodersen MC55 AT Command Manual page 352

At command manual
Table of Contents

Advertisement

Notes
The Mobile Equipment storage ''ME'' offers space for 25 short messages, see <mem1>.
''MT'' is the sum of ''ME'' (= 25 locations) and ''SM'' (capacity varies with SIM card). The indices
the ''MT'' storage are dependent on the order selected with
The <mem1>,
<mem2>
The user should be aware that the setting ''MT'' involves ''ME'' and ''SM'', with ''ME'' being filled up first. If the
''ME'' storage is full, MC55 will proceed with the ''SM'' storage.
Incoming Class 1 short messages (ME specific) will be preferably stored to ''ME'' and may be transferred to
the ''SM'' storage if ''ME'' is used up.
Incoming Class 2 messages (SIM specific) will be stored to the SIM card only, no matter whether or not there
is free ''ME'' space. As a result, the ^SMGO: 2 indication (see AT^SMGO) may be presented without prior indi-
cation of ^SMGO: 1. For more information regarding SIM and ME specific message classes refer to
and the following specifications: GSM 03.38 and 3GPP TS23038.
When
is switched over from ''MT'' to ''SM'' all free ''ME'' locations will be filled with dummy short mes-
<mem3>
sages. This procedure can take up to 35 seconds, until all the 25 records are written.
If switching from ''MT'' to ''SM'' was not finished due to error or user break, the value of
but some of the dummy records remain in the ''ME'' storage. These records have to be deleted manually.
When
equals ''SM'', do not delete the dummy messages in the ''ME''. storage. They will be automat-
<mem3>
ically deleted when you switch back from ''SM'' to ''MT''. Again, this may take up to 35 seconds.
If switching from ''SM'' to ''MT'' was not finished due to an error or user break, the value of
''SM'', but the ''ME'' storage will no longer be filled with dummy records. New incoming short messages may
now be written to the ''ME'' storage, if ''SM'' is already full. To avoid this, repeat the
soon as possible to switch
records and issue AT+CPMS=MT,MT,MT.
Multiplexer: In Multiplex mode or when the two physical serial interfaces are connected, the parameter
will be the same on all instances, but the settings of
<mem3>
/ interface. As a result, changes on parameter
ferences values for other instanes can result in not desired behaviours like different outputs for
so on.
While
equals ''SM'' and
<mem3>
''ME'', the freed space on ''ME'' is reclaimed for new incoming short messages, when there is no space left on
the ''SM'' storage. As it is often the clients concern to have received short messages stored only to the SIM
card, inconsistent settings should be generally avoided. This can be achieved simply by using the same
parameter for all memory indices.
Users should be aware that when using this AT command quickly after SIM PIN authentication the SIM data
may not yet be accessible, resulting in a short delay before the requested AT command response is returned.
See Section 20.1,
Restricted access to SIM data after SIM PIN authentication
The indices
<index>
MC55_ATC_V04.00
Confidential / Released
and
parameter will be stored in non-volatile memory.
<mem3>
back to ''MT''. As an alternative, you can manually delete the dummy
<mem3>
<mem1>
equals ''ME'' it is possible that, after deleting short messages from
<mem1>
of the storage are dependent on the order selected with AT^SSMSS.
Page 352 of 475
AT^SSMSS
and
<mem1>
<mem2>
and/or
befor activating the multiplexer or dif-
<mem2>
for further detail.
<index>
<dcs>
remains ''MT'',
<mem3>
remains
<mem3>
command as
AT+CPMS
may vary on each channel
and
AT+CMGL
3/17/06
of

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brodersen mc55

Table of Contents