ATS7 Set number of seconds to wait for connection completion

specifies the number of seconds the TA will wait for the completion of the call setup when answering or
ATS7
originating a data call. Also referred to as "no answer timeout". To put it plainly, this is the time to wait for the
carrier signal. If no carrier signal is received within the specified time, the TA hangs up.
Syntax
Read Command
ATS7?
Response(s)
<n>
OK
Write Command
ATS7=<n>
Response(s)
OK
ERROR
Reference(s)
V.250
Parameter Description
(num)(&W)(&V)
<n>
Number of seconds to wait for connection completion
(&F)
000...060
Notes
Command
is only applicable to data calls.
ATS7
Values greater than 60 cause no error, but
The correlation between
call setup may fail.
ATS0=<n>
Example: Call setup may fail if ATS7=30 and ATS0=20.
MC55_ATC_V04.00
Confidential / Released
PIN
will be restored to the maximum value of 60.
<n>
and
is important. If the called party has specified a high value for
ATS7
ATS0