AT^SBV Battery/Supply Voltage

The
execute command allows to monitor the supply (or battery) voltage of the module. The voltage is
AT^SBV
continuously measured at intervals depending on the operating mode of the RF interface. The duration of a mea-
surement period ranges from 0.5s in TALK / DATA mode up to 50s when MC55 is in IDLE mode or Limited Ser-
vice (deregistered). The displayed value is averaged over the last measuring period before the
command was executed.
The measurement is related to the test points of BATT+ and GND, both accessible on the bottom of the module.
Refer to [1] for information on the module's test points.
Syntax
Test Command
AT^SBV=?
Response(s)
OK
ERROR
+CME ERROR:
Exec Command
AT^SBV
Response(s)
^SBV:
<value>
OK
ERROR
+CME ERROR:
Reference(s)
SIEMENS
Parameter Description
(num)
<value>
Supply (or battery) voltage in mV
MC55_ATC_V04.00
Confidential / Released
PIN
ASC0 ASC1
!
%
%
Page 433 of 475