At^sacm Advice Of Charge And Query Of Acm And Acmmax - Siemens Brodersen MC55 AT Command Manual

At command manual
Table of Contents

Advertisement

9.2

AT^SACM Advice of charge and query of ACM and ACMmax

Syntax
Test Command
AT^SACM=?
Response(s)
^SACM:(list of supported <n>s)
OK
Exec Command
AT^SACM
Response(s)
^SACM: <n>, <acm>,
OK
ERROR
+CME ERROR: <err>
Write Command
AT^SACM=<n>
Response(s)
OK
ERROR
+CME ERROR: <err>
Reference(s)
SIEMENS
Unsolicited Result Code
+CCCM:
<ccm>
When activated, an unsolicited result code is sent when the CCM value changes, but not more often than every
10 seconds.
Command Description
The execute command can be used to query the current mode of the Advice of Charge supplementary service,
the SIM values of the accumulated call meter (ACM) and accumulated call meter maximum (ACMmax).
The write command enables or disables the presentation of unsolicited result codes to report the call charges.
Parameter Description
(num)(&W)(&V)
<n>
(&F)
[0]
1
(str)(&V)
<acm>
Three bytes of the current ACM value in hexadecimal format (e.g. "00001E" indicates decimal value 30) 000000-
FFFFFF
(str)(&V)
<acmMax>
Three bytes of the max. ACM value in hexadecimal format (e.g. "00001E" indicates decimal value 30) 000000
disable ACMmax feature 000001-FFFFFF
MC55_ATC_V04.00
Confidential / Released
<acmMax>
suppress unsolicited result code
display unsolicited result code
Page 192 of 475