Brother KE-430HX Service Manual page 33

Electronic direct drive lockstitch bar tacker electronic direct drive lockstitch button sewer
Hide thumbs Also See for KE-430HX:
Table of Contents

Advertisement

No.
Setting range
582
ON/OFF
-150 − 150
583
(degrees)
-110 − 40
584
(degrees)
585
0 − 500
587
0 − 300
0 − 50
588
(ms)
0 − 50
589
(ms)
590
5 − 10
0 − 580
591
(degrees)
200 − 700
592
(sti/min)
0 − 15
593
(ms)
Error processing settings (600 − 699)
No.
Setting range
650
0 − 2
*1
651
ON/OFF
652
ON/OFF
654
ON/OFF
655
ON/OFF
OFF, 2 − 30
657
(seconds)
*1: This is not initialized during initialization mode.
Initial value
Setting units
ON
-
0
5
40
5
470
1
0
1
35
1
20
1
5
1
430H: 280
5
438H: 270
600
100
8
1
Initial
Setting units
value
0
1
OFF
-
ON
-
OFF
-
ON
-
OFF
2
KE-430HX/KE-430HS, BE-438HX/BE-438HS
Setting details
Upper thread tension tightening at the sewing start
ON: Enabled
OFF: Disabled
Upper thread tension change (tightening) angle offset at the
sewing start
Upper thread tension release angle offset at the sewing end
Upper thread tension value (tightening) at the sewing start
Upper thread tension value (release) at the sewing start
Thread trimmer motor ON timing
Thread trimmer motor ON time
Thread trimmer motor holding force
Specified final speed output angle offset
Last stitch sewing speed for upper shaft motor
Speed change delay until thread nipper operation is complete
* If the thread nipper device is not to operate, set to "0".
Setting details
Error release method when operation has stopped
0: Press the RESET key on the operation panel.
1: Press the RESET key on the operation panel or the STOP
switch (available by special order).
2: Press the RESET key on the operation panel or the external
switch (EXIN2).
Needle stop position when sewing is interrupted by the STOP
switch (available by special order)
ON: Needle stops in the up position.
OFF: Needle stops in the down position.
Thread trimming operation when sewing is paused
ON: Thread trimming is carried out when the pause is
canceled.
OFF: Thread trimming is not carried out when the pause is
canceled.
Use of STOP switch (available by special order)
ON: Used
OFF: Not used
Needle up stop position monitoring function
ON: Enabled
OFF: Disabled
Time from error occurring to buzzer stopping
OFF: Buzzer does not stop.
2 − 30: Buzzer stops after the specified time.
4. FUNCTION SETTINGS
22

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Ke-430hsBe-438hsBe-438hx

Table of Contents