No.
Setting range
0.0 − 30.0
461
(mm)
462
0 − 8
463
ON/OFF
465
1 − 3
469
ON/OFF
470
ON/OFF
430H: 10 − 17
(mm)
471
438H: 6 − 13
(mm)
430H: 1 − 17
(mm)
472
438H: 1 − 13
(mm)
473
0/1
Setting
Initial value
units
430H: 30.0
0.1
438H: 6.4
0
1
OFF
-
1
1
OFF
-
OFF
-
14
1
10
1
1
430H: 0
0
KE-430HX/KE-430HS, BE-438HX/BE-438HS
Sewing area limit in Y direction
* Setting range is 0.0 to 40.0 (mm) when No.473 is set to "1".
Zoom reference point
0: Center of sewing frame
1: Sewing start point
2: Center of pattern
3: Front of pattern center
4: Back of pattern center
5: Back-left corner of sewing area
6: Front-left corner of sewing area
7: Back-right corner of sewing area
8: Front-right corner of sewing area
Zoom for pitch of less than 1 mm
ON: Bar tacking stitch lengths (pitch less than approx. 1 mm) are
also zoomed.
OFF: Bar tacking stitch lengths (pitch less than approx. 1 mm) are
not zoomed.
Setting offset amount for sewing pattern
1: The offset amount is initialized when the power is turned off
and when the program number, X-scale or Y-scale is changed.
2: The offset amount is retained when the power is turned off, but
is initialized when the program number, X-scale or Y-scale is
changed.
3: The offset amount can be set for each program using
parameters.
The offset amount is retained when the power is turned off and
when the program number, X-scale or Y-scale is changed.
Tension value setting
ON: Operation is according to individual tension values.
* Setting is only possible for additional programs
* For standard programs, the common tension value is used.
* For user programs and cycle programs, this setting is
enabled when additional programs are used, and when
standard programs are used, the common tension value is
used.
OFF: Operation is according to the common tension value.
* Switching to pattern editing mode is not possible.
* If a tension value is set using a programmer, etc., the
setting is ignored.
Work clamp/button clamp height setting for each program
ON: Work clamp/button clamp height is set separately for each
program.
OFF: A common work clamp/button clamp height is set for all
programs.
* The work clamp/button clamp height is set by Nos. 471
and 472.
Work clamp/button clamp raise position setting
* Enabled when No. 470 is set to "OFF".
Work clamp/button clamp intermediate drop position setting
* Enabled when No. 470 is set to "OFF".
Sewing area (430H only)
0: 40×30mm
1: 50×40mm
4. FUNCTION SETTINGS