Brother KE-430HX Service Manual page 32

Electronic direct drive lockstitch bar tacker electronic direct drive lockstitch button sewer
Hide thumbs Also See for KE-430HX:
Table of Contents

Advertisement

4. FUNCTION SETTINGS
Device settings (500 − 599)
No.
Setting range
500
ON/OFF
OFF,
550
100 − 2000
(ms)
OFF, 1 − 3
551
(stitches)
554
ON/OFF
555
ON/OFF
565
0 − 2
*1
566
ON/OFF
*2
567
ON/OFF
-80 − 115
580
(degrees)
-160 − 110
581
(degrees)
*1: This is not displayed for models with digital tension.
*2: This is not initialized during initialization mode.
21
Initial value
Setting units
OFF
OFF
100
430H-05: 1
OFF
OFF
OFF
0
430H-01: ON
430H-03: ON
430H-05: OFF
430H-0K: ON
438H: OFF
OFF
10
-110
KE-430HX/KE-430HS, BE-438HX/BE-438HS
Thread nipper operation
ON: Enabled
* However, all of the following conditions must be
satisfied.
Memory switch No. 100 = ON
-
Memory switch No. 566 = ON
Slow start speed is 8 or 9
Sewing speed is 1500 sti/min. or more
OFF: Disabled
Output continue time for needle cooler device when sewing
machine is stopped
OFF: Needle cooler device is not used
100 to 2000: Output is continued for the specified time.
Upper thread tension release at the sewing start
* Only enabled when the thread nipper is not operating.
1
OFF: Not released
1 to 3: Released during the specified number of stitches.
Use of the thread breakage sensor (available by special order)
-
ON: Used
OFF: Not used
Sewing start sensing sensitivity for thread breakage sensor
(available by special order)
-
ON: 10 stitches at sewing start
OFF: 5 stitches at sewing start
Tension release solenoid power setting
0: Standard
1
1: Greater force
2: Maximum
Thread nipper device installation
ON: Installed
* The thread nipper device only operates when all of the
following conditions are satisfied.
Memory switch No. 100 = ON
Memory switch No. 500 = ON
-
Slow start speed is 8 or 9
Sewing speed is 1500 sti/min. or more
OFF: Not installed
NOTE:
If the thread nipper device is installed, do not set this to
"OFF". If this is not observed, damage may occur.
Upper thread tension during feeding while upper shaft is
stopped
-
ON: Not released
OFF: Released
5
Nip timing offset for thread nipper device
5
Release timing offset for thread nipper device
Setting details

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Ke-430hsBe-438hsBe-438hx

Table of Contents