Brother KE-430HX Service Manual page 215

Electronic direct drive lockstitch bar tacker electronic direct drive lockstitch button sewer
Hide thumbs Also See for KE-430HX:
Table of Contents

Advertisement

Error status #9 Error code appears on the display when the foot switch is depressed.
Probable causes
1. If the work clamp pulse motor
does not operate and "E300" is
displayed, there is a malfunction of
the power supply motor PCB.
2. If the work clamp pulse motor
does not move and "E300" is
displayed, there is a malfunction of
the main PCB.
3. If the work clamp pulse motor
moves slightly and "E300" is
displayed, there is a malfunction of
the encoder.
4. If the work clamp pulse motor
does not move and "E300" is
displayed, there is a malfunction of
the pulse motor and cord.
Check/ repair/ adjust
Disconnect connector P2 (POWER) from the
power supply motor PCB, and then turn on the
power switch and check LD1 (red) on the power
supply motor PCB.
OK if illuminated.
After checking, turn off the power switch, wait for
five minutes or more, and then insert connector
P2 (POWER) into the power supply motor PCB.
a. With LD1 (red) on the main PCB unlit,
disconnect connector P22 (POWER) from the
main PCB, and check the continuity between
terminals 1-3 of P22.
OK if  ohms.
b. Disconnect the relay connector (black and
connected
connecting the pulse motor to the main PCB,
and check the continuity between terminals
2-3 and 5-6 of the connector.
OK if  ohms.
c. Insert P22 and the black relay connector for
connecting the pulse motor connection to the
main PCB, turn on the power switch and then
check LD1 (red) on the power supply motor
PCB.
OK if illuminated.
If LD1 is illuminated during the check in step 1
in #9 but it does not illuminate when the black
relay connector for connecting the pulse motor
and P22 are connected, there is a malfunction
of the main PCB.
d. Check LD1 (red) on the main PCB.
OK if illuminated.
4178B
4183B
a. Check that connector P6 (P-ENC) is inserted
into the main PCB and that the color matches.
b. Check the encoder input while referring to
"4-4. Checking input".
a. Disconnect the relay connector (black and
connected
connecting the pulse motor to the main PCB,
and
measure
terminals 2-3 and 5-6 of the cord connector.
OK if 1.89-2.3 ohms (2.1 ohms +/- 10%).
b. If step a. (above) is OK, there is a malfunction
of the main PCB.
4184B
KE-430HX/KE-430HS, BE-438HX/BE-438HS
to
XT5/XT2/XT3/XT1)
to
XT5/XT2/XT3/XT1)
the
resistance
between
14. ELECTRIC MECHANISM
Parts to be replaced
Power supply motor PCB
assembly
Main PCB assembly
for
Pulse motor P assembly
Main PCB assembly
Pulse motor P assembly
for
Main PCB assembly
204

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Ke-430hsBe-438hsBe-438hx

Table of Contents