14. ELECTRIC MECHANISM
Error status #8 Error code appears on the display when the foot switch is depressed.
Probable causes
1. If the Y feed does not move and
"E210" is displayed, there is a
malfunction of the power supply
motor PCB.
2. If the Y feed does not move and
"E210" is displayed, there is a
malfunction of the main PCB.
3. If the Y feed moves slightly and
"E210" is displayed, there is a
malfunction of the encoder.
4. If the Y feed does not move and
"E210" is displayed, there is a
malfunction of the pulse motor and
cord.
203
Check/ repair/ adjust
Disconnect connector P2 (POWER) from the
power supply motor PCB, and then turn on the
power switch and check LD1 (red) on the power
supply motor PCB.
OK if illuminated.
After checking, turn off the power switch, wait for
five minutes or more, and then insert connector
P2 (POWER) into the power supply motor PCB.
a. With LD1 (red) on the main PCB unlit,
disconnect connector P22 (POWER) from the
main PCB, and check the continuity between
terminals 1-3 of P22.
OK if  ohms.
b. Disconnect the relay connector (red and
connected
connecting the pulse motor to the main PCB,
and check the continuity between terminals
2-3 and 5-6 of the connector.
OK if  ohms.
c. Insert P22 and the red relay connector for
connecting the pulse motor to the main PCB,
turn on the power switch and then check LD1
(red) on the power supply motor PCB.
OK if illuminated.
If LD1 is illuminated during the check in step 1
in #8 but it does not illuminate when P22 is
connected, there is a malfunction of the main
PCB.
d. Check LD1 (red) on the main PCB.
OK if illuminated.
4178B
4181B
a. Check that connector P3 (Y-ENC) is inserted
into the main PCB and that the color matches.
b. Check the encoder input while referring to
"4-4. Checking input".
a. Disconnect the relay connector (red and
connected
connecting the pulse motor to the main PCB,
and
measure
terminals 2-3 and 5-6 of the cord connector.
OK if 1.89-2.3 ohms (2.1 ohms +/- 10%).
b. If step a. (above) is OK, there is a malfunction
of the main PCB.
4182B
KE-430HX/KE-430HS, BE-438HX/BE-438HS
to
XT9/XT7/XT6/XT4)
to
XT9/XT7/XT6/XT4)
the
resistance
between
Parts to be replaced
Power supply motor PCB
assembly
Main PCB assembly
for
Pulse motor Y assembly
Main PCB assembly
Pulse motor Y assembly
for
Main PCB assembly

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Ke-430hsBe-438hsBe-438hx

Table of Contents