dot1x test timeout

dot1x test timeout
Syntax Description
Defaults
Command Modes
Command History
Usage Guidelines
Examples
Related Commands
Catalyst 3750-X and 3560-X Switch Command Reference
2-184
Downloaded from
www.Manualslib.com
Use the dot1x test timeout global configuration command on the switch stack or on a standalone switch
to configure the timeout used to wait for EAPOL response from a port being queried for IEEE 802.1x
readiness.
dot1x test timeout timeout
timeout
The default setting is 10 seconds.
Global configuration
Release
Modification
12.2(53)SE2
This command was introduced.
Use this command to configure the timeout used to wait for EAPOL response.
There is not a no form of this command.
This example shows how to configure the switch to wait 27 seconds for an EAPOL response:
Switch# dot1x test timeout 27
You can verify the timeout configuration status by entering the show run privileged EXEC command.
Command
dot1x test eapol-capable
[interface
interface-id]
manuals search engine
Chapter 2
Time in seconds to wait for an EAPOL response. The range is from
1 to 65535 seconds.
Description
Checks for IEEE 802.1x readiness on devices connected to
all or to specified IEEE 802.1x-capable ports.