Dot1X Timeout - Cisco Catalyst 2960 Command Reference Manual

Hide thumbs Also See for Catalyst 2960:
Table of Contents

Advertisement

Chapter 2
Catalyst 2960 Switch Cisco IOS Commands

dot1x timeout

Use the dot1x timeout interface configuration command to set IEEE 802.1x timers. Use the no form of
this command to return to the default setting.
Syntax Description
quiet-period seconds
reauth-period seconds
server-timeout seconds
supp-timeout seconds
tx-period seconds
Defaults
These are the default settings:
reauth-period is 3600 seconds.
quiet-period is 60 seconds.
tx-period is 30 seconds.
supp-timeout is 30 seconds.
server-timeout is 30 seconds.
Command Modes
Interface configuration
Command History
Release
12.2(25)FX
Usage Guidelines
You should change the default value of this command only to adjust for unusual circumstances such as
unreliable links or specific behavioral problems with certain clients and authentication servers.
The dot1x timeout reauth-period interface configuration command affects the behavior of the switch
only if you have enabled periodic re-authentication by using the dot1x reauthentication interface
configuration command.
During the quiet period, the switch does not accept or initiate any authentication requests. If you want
to provide a faster response time to the user, enter a number smaller than the default.
78-16882-01
dot1x timeout {quiet-period seconds | reauth-period seconds | server-timeout seconds |
supp-timeout seconds | tx-period seconds}
no dot1x timeout {quiet-period | reauth-period | server-timeout | supp-timeout | tx-period}
Number of seconds that the switch remains in the quiet state following a
failed authentication exchange with the client. The range is 1 to 65535.
Number of seconds between re-authentication attempts. The range is 1
to 65535.
Number of seconds that the switch waits for the retransmission of packets
by the switch to the authentication server. The range is 30 to 65535.
Number of seconds that the switch waits for the retransmission of packets
by the switch to the IEEE 802.1x client. The range is 30 to 65535.
Number of seconds that the switch waits for a response to an
EAP-request/identity frame from the client before retransmitting the
request. The range is 15 to 65535.
Modification
This command was introduced.
Catalyst 2960 Switch Command Reference
dot1x timeout
2-75

Advertisement

Table of Contents
loading

Table of Contents