Cisco Catalyst 3560-X Command Reference Manual page 773

Hide thumbs Also See for Catalyst 3560-X:
Table of Contents

Advertisement

Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
OL-21522-02
Downloaded from
www.Manualslib.com
The Gi1/0/12 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
The Gi1/0/13 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port.
This is an example of output from the show power inline police interface-id command on a standalone
switch.
Table 2-47
describes the output fields.
Switch> show power inline police gigabitethernet0/4
Interface Admin
Oper
State
State
--------- ------ ---------- ---------- ---------- ------ -----
Gi0/4
auto
power-deny log
Table 2-47
show power inline police Field Descriptions
Field
Description
Available
The total amount of configured power
Used
The amount of configured power allocated to PoE ports in watts.
Remaining
The amount of configured power in watts that is not allocated to ports in the
system. (Available – Used = Remaining)
Admin State
Administration mode: auto, off, static.
Oper State
Operating mode:
errdisable—Policing is enabled.
faulty—Device detection on a powered device is in a faulty state.
off—No PoE is applied.
on—The powered device is detected, and power is applied.
power-deny—A powered device is detected, but no PoE is available, or the
real-time power consumption exceeds the maximum power allocation.
Note
Admin Police
Status of the real-time power-consumption policing feature:
errdisable—Policing is enabled, and the switch shuts down the port when the
real-time power consumption exceeds the maximum power allocation.
log—Policing is enabled, and the switch generates a syslog message when
the real-time power consumption exceeds the maximum power allocation.
none—Policing is disabled.
Oper Police
Policing status:
errdisable—The real-time power consumption exceeds the maximum power
allocation, and the switch shuts down the PoE port.
log—The real-time power consumption exceeds the maximum power
allocation, and the switch generates a syslog message.
n/a—Device detection is disabled, power is not applied to the PoE port, or no
policing action is configured.
ok—Real-time power consumption is less than the maximum power
allocation.
manuals search engine
Admin
Oper
Cutoff Oper
Police
Police
Power
n/a
4.0
The operating mode is the current PoE state for the specified PoE port,
the specified stack member, or for all PoE ports on the switch.
Catalyst 3750-X and 3560-X Switch Command Reference
show power inline
Power
0.0
1
on the switch in watts (W).
2-741

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3750-x

Table of Contents