Mode - Cisco Catalyst 3560-X Command Reference Manual

Hide thumbs Also See for Catalyst 3560-X:
Table of Contents

Advertisement

Chapter 2
Catalyst 3750-X and 3560-X Switch Cisco IOS Commands

mode

Note
Syntax Description
Defaults
Command Modes
Command History
Usage Guidelines
Note
OL-21522-02
Downloaded from
www.Manualslib.com
To configure power stack mode for the power stack, use the mode power-stack configuration command
To return to the default settings, use the no form of the command.
mode {redundant | power-shared} [strict]
no mode
This command is available only on Catalyst 3750-X switch stacks running the IP base or IP services
feature set.
redundant
power-shared
strict
The default modes are power-shared and nonstrict.
Power-stack configuration
Release
12.2(53)SE2
To access power-stack configuration mode, enter the stack-power stack power stack name global
configuration command.
Entering the no mode command sets the switch to the defaults of power-shared and non-strict mode.
For stack power, available power is the total power available for PoE from all power supplies in the
power stack, budgeted power is the power allocated to all powered devices connected to PoE ports in the
stack, and consumed power is the actual power consumed by the powered devices.
In power-shared mode, all of the input power can be used for loads, and the total available power
appears as one large power supply. The power budget includes all power from all supplies. No power is
set aside for power supply failures. If a power supply fails, load shedding (shutting down of powered
devices or switches) might occur.
manuals search engine
Sets the power stack to operate in redundant mode. The largest power supply
is removed from the power pool to be used as backup power in case one of
the other power supplies fails.
Sets the power stack to operate in power-shared mode. This is the default.
(Optional) Configures the power stack mode to run a strict power budget.
The stack power needs cannot exceed the available power.
Modification
This command was introduced.
Catalyst 3750-X and 3560-X Switch Command Reference
mode
2-401

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3750-x

Table of Contents