@GOF / @SOF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
@GMT / @SMT
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set masking time after automatic switching of input channel.
Setting
Command
example
Response
Description Setting the masking time to 2000 ms. (2 sec.) for OUT1, 10000 ms. (10 sec.) for
Remarks
MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
Priority of input channel automatic switching (ON to OFF)
@GOF, out
@GOF, out, in1_priority, in2_priority, in3_priority, in4_priority, in5_priority,
in6_priority, in7_priority, in8_priority
@SOF, out_1, in1_priority, in2_priority・・・, in8_priority (, out_2, in1_priority・・・)
@SOF, out_1, in1_priority, in2_priority・・・, in8_priority (, out_2, in1_priority・・・)
out, out_1-2: Output channel
1 = OUT1, 2 = OUT2
in1_priority – in8_priority: Priority
0 = OFF, 1 = priority (high) to 8 = priority (low)
@GOF,1
@GOF,1,1,2,3,4,5,6,7,8
Getting the set priority of OUT1's automatic switching.
IN1>IN2>・・・>IN8
@SOF,1,8,7,6,5,4,3,2,1
@SOF,1,8,7,6,5,4,3,2,1
Setting the priority of OUT1's automatic switching to IN8>IN7>・・・>IN1.
Masking time after automatic switching of input channel
@GMT
@GMT, time_1, time_2
@SMT, ch_1, time_1 (, ch_2, time_2)
@SMT, ch_1, time_1 (, ch_2, time_2)
time_1-2: Masking time
0 = 0 sec. to 999999 = 999.999 sec. [Default] 0 sec.
ch_1-2: Output channel
0 = All outputs, 1 = OUT1, 2 = OUT2
@GMT
@GMT,2000,10000
Automatic switching is not performed until the following time passes:
OUT1: 2000 ms. (2 sec.), OUT2: 10000 ms. (10 sec.)
@SMT,1,2000,2,2000
@SMT,1,2000,2,2000
OUT2.
57