IDK MSD-701UHD Command Reference Manual page 75

High-performance digital multi switchers
Hide thumbs Also See for MSD-701UHD:
Table of Contents

Advertisement

[Table 3.1] Parameter of RS-232C communication settings
Value
Communication
0
4800 8 NONE 1
1
4800
8 NONE 2
2
4800
8
ODD
1
3
4800
8
ODD
2
4
4800
8 EVEN 1
5
4800
8 EVEN 2
6
4800
7 NONE 1
7
4800
7 NONE 2
8
4800
7
ODD
1
9
4800
7
ODD
2
10
4800
7 EVEN 1
11
4800
7 EVEN 2
@GCF / @SCF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set operation modes
Setting
Command
example
Response
Description Setting RS-232C connector to TRANSMITTER mode.
Remarks
MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
Value
Communication
12
9600
8 NONE 1
13
9600
8 NONE 2
14
9600
8
ODD
1
15
9600
8
ODD
2
16
9600 8 EVEN 1
17
9600 8 EVEN 2
18
9600 7 NONE 1
19
9600 7 NONE 2
20
9600 7
ODD
1
21
9600 7
ODD
2
22
9600 7 EVEN 1
23
9600 7 EVEN 2
RS-232C communication mode
@GCF
@GCF, mode
@SCF, port, mode
@SCF, port, mode
mode: Operation mode
0 = RECEIVER mode [Default], 1 = TRANSMITTER mode
port: RS-232C channel
1 = RS-232C connector, 2 = OUT1B connector,
3 = OUT2B connector,
@GCF
@GCF,1
TRANSMITTER mode
@SCF,1,1
@SCF,1,1
These commands are only for RS-232C.
If IP address or RS-232C communication setting is changed, the communication
may be disabled. Change the environmental settings based on the MSD settings.
Value
Communication
24
19200 8 NONE 1
25
19200 8 NONE 2
26
19200 8
ODD
1
27
19200 8
ODD
2
28
19200 8 EVEN 1
29
19200 8 EVEN 2
30
19200 7 NONE 1
31
19200 7 NONE 2
32
19200 7
ODD
1
33
19200 7
ODD
2
34
19200 7 EVEN 1
35
19200 7 EVEN 2
4 = IN8 connector
Value
Communication
36
38400 8 NONE 1
37
38400 8 NONE 2
38
38400 8
ODD
1
39
38400 8
ODD
2
40
38400 8 EVEN 1
41
38400 8 EVEN 2
42
38400 7 NONE 1
43
38400 7 NONE 2
44
38400 7
ODD
1
45
38400 7
ODD
2
46
38400 7 EVEN 1
47
38400 7 EVEN 2
75