IDK MSD-701UHD Command Reference Manual page 89

High-performance digital multi switchers
Hide thumbs Also See for MSD-701UHD:
Table of Contents

Advertisement

@GCC / @SCC
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting control commands that will be executed when the MSD is powered on.
Setting
Command
example
Response
Description Executing in order of control command 5, 2, and 1 when the MSD is powered on.
Remarks
MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
Control command link
@GCC, event
@GCC, event, c_1 (, c_2, c_3・・・)
@SCC, event, c_1 (, c_2, c_3・・・)
@SCC, event, c_1 (, c_2, c_3・・・)
event: Control command execution condition
For settable values, see the [Table 3.2].
c_1-10 : Send command
0 = Not link [Default], 1 to 32 = Control command 1 to 32
Control commands that are registered in one of the following commands can be
linked.
@GEC / @SEC Control command (Communication command),
@GEC / @SEC Control command (Displaying received data),
@GEC / @SEC Control command (contact closure),
@GEC / @SEC Control command (CEC),
@GCC,19
@GCC,19,5,2,1
Executing in order of control command 5, 2, and 1.
@SCC,19,5,2,1
@SCC,19,5,2,1
89