MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
@GGW / @SGW
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set gateway address.
Setting
Command
example
Response
Description Setting gateway address to 192.168.1.254.
Remarks
78
Gateway address
@GGW
@GGW, unit_1, unit_2, unit_3, unit_4
@SGW, unit_1, unit_2, unit_3, unit_4
@SGW, unit_1, unit_2, unit_3, unit_4
unit_1: Upper bit of the gateway address to unit_4: lower bit of the gateway
address
0 to 255 = 8 bit (Decimal notation) [Default] 192.168.1.200
@GGW
@GGW,192,168,1,254
Gateway address: 192.168.1.254
@SGW,192,168,1,254
@SGW,192,168,1,254
If IP address or RS-232C communication setting is changed, the communication
may be disabled. Change the environmental settings based on the MSD settings.