MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
@GFD
Getting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the actual sampling frequency.
Remarks
@GDO / @SDO
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the audio output connectors' settings.
Setting
Command
example
Response
Description Setting OUT1 to output to only analog audio output connectors.
Remarks
64
Actual sampling frequency
@GFD
@GFD, frequency_1, frequency_2
frequency_1-2: Sampling frequency
2 = 32 kHz,
3 = 44.1 kHz,
5 = 88.2 kHz,
6 = 96 kHz,
@GFD
@GFD,6,4
OUT1: 96 kHz, OUT2: 48 kHz
"@GSF / @SSF Sampling frequency" is set to "AUTO", the sampling frequency
that is output actually is returned. If it is set to value other than "AUTO", the set
sampling frequency is returned.
Audio output connector
@GDO
@GDO, out_1, out_2
@SDO, ch_1, out_1, (, ch_2, out_2)
@SDO, ch_1, out_1, (, ch_2, out_2)
out_1-2: Audio output connector
0 = Only to analog audio output connectors,
1 = To HDMI output connectors and HDBaseT output connectors,
2 = To analog audio connectors, HDMI output connectors, and
HDBaseToutput connectors [Default]
ch_1-2: Output channel
0 = All outputs, 1 = OUT1, 2 = OUT2
@GDO
@GDO,0,1
OUT1: only to analog audio output connectors
OUT2: to HDMI output connectors and HDBaseT output connectors
@SDO,1,0
@SDO,1,0
-
4 = 48 kHz,
7 = 192 kHz