3.3 Detailed descriptions

Commands for MSD-802UHD are shown in this section. For other models, use appropriate commands
according to the number of inputs and outputs.

3.3.1 Error status

@ERR
Description
Response
Parameter
Getting
Command
example
Response
Description
Remarks
MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
Error status
Response in case the command is not executed.
@ERR, error
error: Error status
1 = Erroneous parameter format or value
2 = Undefined command or wrong format
3 = Currently cannot be used.
4 = Not used.
5 = The command could not be executed, because the control command was
not registered.
6 = The command could not be processed since another command was being
executed.
7 = Automatic measurement of input timing failed.
8 = Loading EDID from the sink device failed.
9 = Not used.
10 = The control command was stopped according to the stop condition.
11 = The control command was stopped since the number of retries exceeded
the set value of "RETRY".
12 = The control command of PJLink was stopped since the password did not
match.
13 = The image could not be captured since the image size to be captured
exceeded the reserved memory size.
14 = Capturing input image failed.
@IOS
@ERR,2
@IOS is sent.
Command format error.