Table 32. Memory Error Handling - Post - Intel S7000FC4UR Technical Product Specification

Hide thumbs Also See for S7000FC4UR:
Table of Contents

Advertisement

Intel® Server System S7000FC4UR TPS
Error
POST
Scenario
Behavior
®
Intel
MemBIST
Uncorrectable Error
SEL message
Uncorrectable Error
identifying FBDIMM
(UE / hard error)
location(s)
POST Error Manager
0x852x, 0x853x
®
Intel
MemBIST
Uncorrectable Error
SEL message
Channel Error
identifying FBDIMM
location(s)
Revision 1.0
Table 32. Memory Error Handling — POST
System Event Log (SEL)
DIMM Fault LED
System Fault LED
UE POST code
DIMM LED:
DIMM Failed POST
On for the
code
failed FBDIMM
only
SEL messages
identifying FBDIMM
System Fault LED:
location(s)
No change
UE POST code
DIMM LED:
DIMM Failed POST
On for all
code
affected
FBDIMMs
SEL messages
identifying FBDIMM
System Fault LED:
location(s)
No change
IPMI Memory RAS
Behavior
Set DIMM State:
DIMM failure status = Y
DIMM disabled status = Y
Set Memory RAS Redun. State
Set RAS Config Information:
No change
Set DIMM State:
DIMM failure status = Y
DIMM disabled status = Y
Set Memory RAS Redun. State
Set RAS Config Information:
No change
BIOS Initialization
System
Operation
The system continues to boot if good
memory is found. If no good memory is
found, the system emits a beep code,
displays a POST diagnostic LED
message, and halts the system.
The system:
Disables all FBDIMMs on the
FBDIMM channel that failed.
Continues to function normally if
there are good FBDIMMs to be
found on the other channel or
branch
Lights fault LEDs for all FBDIMMs,
starting from the first, that failed
MemBIST irrespective of whether
these DIMM sockets are populated
or not. This is to indicative a
broader-level channel or branch
failure.
133