Sign In
Upload
Manuals
Brands
Intel Manuals
Server
M50CYP2UR Series
Intel M50CYP2UR Series Manuals
Manuals and User Guides for Intel M50CYP2UR Series. We have
1
Intel M50CYP2UR Series manual available for free PDF download: System Integration And Service Manual
Intel M50CYP2UR Series System Integration And Service Manual (162 pages)
Brand:
Intel
| Category:
Server
| Size: 12 MB
Table of Contents
Table of Contents
7
1 Introduction
15
Reference Documents and Support Collaterals
17
Table 1. Intel® Server M50CYP Family Reference Documents and Support Collaterals
17
2 Essential System Component Installation and Service
19
Chassis Component Identification
20
System Cover Removal / Installation
20
System Cover Removal
20
Figure 1. Chassis Component Identification
20
Figure 2. System Top Cover Panel Shipping Screws
21
Figure 3. System Top Cover Removal
21
System Cover Installation
22
Air Duct Removal / Installation
22
Figure 4. System Top Cover Installation
22
Figure 5. Standard Air Duct for Processor Heat Sink with 2U Height
23
Figure 6. Standard Air Duct for Processor Heat Sink with 1U Height
23
Figure 7. GPGPU Air Duct for Processor Heat Sink with 1U Height
23
Air Duct Removal
24
Figure 8. Air Duct Removal
24
Figure 9. GPGPU Air Duct Bracket Removal
24
Air Duct Installation
25
Figure 10. Air Duct Installation
25
Figure 11. GPGPU Air Duct Bracket Installation
25
2.4 Processor Assembly and Installation
26
Figure 12. Supported 2U Processor Heat Sinks
26
Figure 13. Processor Heat Sink Module (PHM) Reference Diagram
27
Processor Heat Sink Module (PHM) Assembly
27
Figure 14. Installing Processor Carrier Clip Onto Processor - Part 1
28
Figure 15. Installing Processor Carrier Clip Onto Processor - Part 2
28
Figure 16. Removing Heat Sink from Its Packaging
29
Figure 17. Setting the Processor Heat Sink Anti-Tilt Wires to the Outward Position
29
Figure 18. Pin 1 Indicator of Processor Carrier Clip
30
Figure 19. Socket Protective Cover Removal
30
Processor Installation
30
Figure 20. PHM Alignment with Socket Assembly
31
Figure 21. PHM Installation Onto Server Board
32
Figure 22. Tighten Heat Sink Fasteners
32
Memory Module Installation
33
DIMM Installation
33
Figure 23. DIMM Blank Removal
33
Figure 24. Memory Module Installation
34
Power Supply Module Installation
35
Figure 25. Power Supply Installation
35
3 Optional Accessory Kit Integration and Service
36
System Cover Removal / Installation
37
System Cover Removal
37
Figure 26. System Top Cover Panel Shipping Screws
37
System Cover Installation
38
Figure 27. System Top Cover Removal
38
Figure 28. System Top Cover Installation
38
Air Duct Removal / Installation
39
Figure 29. Standard Air Duct for Processor Heat Sink with 2U Height
39
Figure 30. Standard Air Duct for Processor Heat Sink with 1U Height
39
Air Duct Removal
40
Figure 31. GPGPU Air Duct for Processor Heat Sink with 1U Height
40
Figure 32. Air Duct Removal
40
Air Duct Installation
41
Figure 33. GPGPU Air Duct Bracket Removal
41
Figure 34. Air Duct Installation
41
Figure 35. GPGPU Air Duct Bracket Installation
42
Riser Card Assembly / Add-In Card Assembly Installation / Removal
43
Figure 36. Bracket for Riser Card on Riser Slot #1- Two Views
43
Figure 37. Bracket for Riser Card on Riser Slot #2- Two Views
44
Figure 38. Bracket for Riser Card on Riser Slot #3- Two Views
44
Figure 39. Riser Card Bracket Removal
45
Riser Card Bracket Removal
45
Figure 40. Riser Card Installation on the Bracket
46
Figure 41. Pcie* Add-In Card Installation for Riser Card on Riser Slot #1 or Riser Slot #3
46
Pcie* Add-In Card Installation
46
Riser Card Installation
46
Figure 42. Pcie* Add-In Card Installation for Riser Card on Riser Slot #2
47
Riser Card Assembly Installation - Riser Slot #1, Riser Slot #2, and Riser Slot #3
48
Drive Removal, Assembly, and Installation
48
Figure 43. Riser Card Assembly Installation
48
Figure 44. 2.5" Drive Bay Components
49
Figure 45. 3.5" Drive Bay Components
49
2.5" SSD Drive Assembly for 7 MM Drives
50
Figure 46. Separating Top and Bottom Parts of Drive Blank
50
Figure 47. Attaching the Drive Blank to 7 MM SSD
50
2.5" SSD Drive Installation
51
Figure 48. 2.5" 7 MM Drive Outside Chassis, Ready for Installation
51
Figure 49. 2.5" 7 MM Drive Installation into 2.5" Drive Bay
51
Figure 50. 2.5" 15 MM Drive Outside Chassis, Ready for Installation
52
Figure 51. 2.5" 15 MM Drive Installation into 2.5" Drive Bay
52
2.5" SSD Drive / Drive Blank Removal
53
3.5" HDD Drive Assembly
53
Figure 52. 2.5" Drive Removal
53
Figure 53. 3.5" Drive Carrier Assembly - Drive Blank / Drive Removal
53
Assembly of 2.5" SSD Drive into a 3.5" Drive Carrier
54
Figure 54. 3.5" Drive Carrier Assembly - Drive Installation to Carrier
54
Figure 55. 3.5" Drive Carrier to 2.5" SSD Bracket - Tab Removal and Mount SSD to Bracket
54
Figure 56. 3.5" Drive Carrier to 2.5" SSD Bracket - Mount Bracket Assembly to Carrier
55
Figure 57. 3.5" Drive Carrier to 2.5" SSD Bracket - Secure SSD to Carrier
55
3.5" Drive Carrier Installation
56
3.5" Drive Carrier Removal
56
Figure 58. 3.5" Drive Carrier Installation
56
Figure 59. 3.5" Drive Carrier Removal
56
Ethernet Network Adapter for OCP* - Installation / Removal
57
OCP* Adapter Bay Filler Removal / Installation
57
Table 2. Supported Intel® Ethernet Network Adapters for OCP
57
Figure 60. OCP* Adapter Bay Filler Removal
58
Figure 61. OCP* Adapter Bay Filler Installation
58
OCP* Adapter with Pull Tab Installation
59
OCP* Adapter with Pull Tab Removal
59
Figure 62. OCP* Adapter with Pull Tab Installation
59
Figure 63. OCP* Adapter with Pull Tab Removal
59
OCP* Adapter with Ejector Latch Installation
60
OCP* Adapter with Ejector Latch Removal
60
Figure 64. OCP* Adapter with Ejector Latch Installation
60
Figure 65. OCP* Adapter with Ejector Latch Removal
60
OCP* Adapter with Internal Lock Installation
61
Figure 66. Internal Lock with Unlock and Lock Orientation
61
Figure 67. OCP* Adapter with Internal Lock Installation
61
OCP* Adapter with Internal Lock Removal
62
M.2 Storage Device Installation / Removal
62
Figure 68. OCP* Adapter with Internal Lock Removal
62
Figure 69. M.2 SSD Connector Location
63
Figure 70. M.2 SSD Installation
63
M.2 SSD Installation
63
M.2 SSD Removal
64
Internal Fixed Mount SATA SSD Installation / Removal
64
Figure 71. M.2 SSD Removal
64
Figure 72. Peripheral Power Connector Identification
65
Figure 73. SATA Ports on Server Board
65
Figure 74. Attaching SSD to Drive Bracket
66
Figure 75. Installing SSD Bracket
66
Internal Fixed Mount SSD Installation
66
Figure 76. Removing SSD Bracket
67
Figure 77. Removing SSD from Bracket
67
Internal Fixed Mount SSD Removal
67
Midplane Card Installation / Removal (Ipc - CYPSWITCHMP)
68
Midplane Card Installation
68
Figure 78. Midplane Card Installation
68
Midplane Card Removal
69
Figure 79. Midplane Card Removal
69
Trusted Platform Module (TPM) Installation
70
Figure 80. Trusted Platform Module (TPM) Installation
70
3.10 Intel® VROC 7.5 Key Installation / Removal
71
Intel® VROC 7.5 (VMD Nvme* RAID) Key Installation
71
Figure 81. Intel® VROC Key Insertion
71
Intel® VROC 7.5 (VMD Nvme* RAID) Key Removal
72
3.11 Intel® SAS Interposer Card and SAS RAID Module Installation / Removal
72
Figure 82. Intel® VROC Key Removal
72
Figure 83. SAS Interposer Card Installation
73
Intel® SAS Interposer Card Installation
73
Figure 84. SAS Interposer Card Removal
74
Intel® SAS Interposer Card Removal
74
Figure 85. Intel® SAS RAID Module Installation
75
Intel® SAS RAID Module Installation
75
Figure 86. Intel® SAS RAID Module Removal
76
Intel® SAS RAID Module Removal
76
3.12 Intel® SAS Expander Card Installation / Removal
77
Intel® SAS Expander Card Installation
77
Figure 87. SAS Expander Card Installation
77
Intel® SAS Expander Card Removal
78
Intel® RAID Maintenance Free Backup Unit (RMFBU) and Mounting Bracket Installation / Removal
78
Figure 88. SAS Expander Card Removal
78
Figure 89. Installing Latch on the Plastic Case
79
Figure 90. Insert Super Cap Battery
79
Intel® RMFBU Mounting Bracket Installation
80
Figure 91. Intel® RMFBU Mounting Bracket Installation - Chassis
80
Figure 92. Intel® RMFBU Mounting Bracket Installation - Air Duct
80
Intel® RMFBU Mounting Bracket Removal
81
Figure 93. Intel® RMFBU Mounting Bracket Removal - Chassis
81
Figure 94. Intel® RMFBU Mounting Bracket Removal - Air Duct
81
4 System Software Updates and Configuration
82
5 System Service - System Features Overview
83
Front Drive Bay Options
83
Figure 95. 8 X 2.5" Front Drive Bay Configuration
83
Figure 96. 16 X 2.5" Front Drive Bay Configuration
83
Figure 97. 24 X 2.5" Front Drive Bay Configuration
83
Figure 98. 12 X 3.5" Front Drive Bay Configuration
83
Back Panel, Front Control Panel, Front I/O Features
84
Figure 99. Back Panel Features
84
Figure 100. Front Control Panel Features
84
Drive Tray LED Identification
85
Figure 101. Front I/O Features
85
Figure 102. 2.5" Hot Swap Drive Slot LED Identification
85
Figure 103. 3.5" Drive Slot LED Identification
85
Table 3. Sas/Sata/Nvme* Drive Status LED States
86
Table 4. Drive Activity LED States
86
Server Board Features
87
Figure 104. Intel® Server Board M50CYP2SBSTD Component / Feature Identification
87
Figure 105. Intel® Light-Guided Diagnostics - LED Identification
88
Figure 106. Exploded View of POST Code Diagnostic, System ID, and System Status Leds
88
System Configuration and Recovery Jumpers
89
Figure 107. Intel® Light-Guided Diagnostics - DIMM Fault Leds
89
Figure 108. Reset and Recovery Jumper Block Locations
89
6 System Service and FRU Replacement
90
System Cover Removal / Installation
90
System Cover Removal
91
Figure 109. System Top Cover Panel Shipping Screws
91
Figure 110. System Top Cover Removal
91
System Cover Installation
92
Air Duct Removal / Installation
92
Figure 111. System Top Cover Installation
92
Figure 112. Standard Air Duct for Processor Heat Sink with 2U Height
93
Figure 113. Standard Air Duct for Processor Heat Sink with 1U Height
93
Figure 114. GPGPU Air Duct for Processor Heat Sink with 1U Height
93
Air Duct Removal
94
Figure 115. Air Duct Removal
94
Figure 116. GPGPU Air Duct Bracket Removal
94
Air Duct Installation
95
Figure 117. Air Duct Installation
95
Figure 118. GPGPU Air Duct Bracket Installation
95
System Fan Assembly Replacement
96
Figure 119. System Fan Assembly Removal
96
Figure 120. System Fan Assembly Installation - Part 1
97
Figure 121. System Fan Assembly Installation - Part 2
97
Individual Fan Replacement
98
Figure 122. Individual Fan Removal or Installation
98
Memory Module Replacement
99
Figure 123. Memory Module Removal
99
Power Supply Module Replacement
100
Figure 124. Memory Module Installation
100
Processor Replacement
101
Figure 125. Power Supply Removal
101
Figure 126. Power Supply Installation
101
Figure 127. PHM Assembly Removal from Processor Socket
102
Figure 128. Reinstall the Socket Cover
102
Processor Heat Sink Module (PHM) and Processor Removal
102
Figure 129. Processor Removal from PHM Assembly
103
Figure 130. Processor Carrier Clip Removal from PHM Assembly
103
PHM and Processor Installation
103
Figure 131. Installing Processor Carrier Clip Onto Processor - Part 1
104
Figure 132. Installing Processor Carrier Clip Onto Processor - Part 2
104
Figure 133. Removing Heat Sink from Its Packaging
105
Figure 134. Processor Heat Sink Anti-Tilt Wires in the Outward Position
105
Figure 135. Pin 1 Indicator of Processor Carrier Clip
106
Figure 136. Socket Protective Cover Removal
106
Figure 137. PHM Alignment with Socket Assembly
107
Figure 138. PHM Installation Onto Server Board
107
Drive Removal, Installation, and Assembly
108
Figure 139. Tighten Heat Sink Fasteners
108
Figure 140. 2.5" Drive Bay Components
109
Figure 141. 3.5" Drive Bay Components
109
2.5" SSD Drive Assembly for 7 MM Drives
110
2.5" SSD Drive Removal
110
Figure 142. Drive Removal
110
Figure 143. Separating Top and Bottom Parts of Drive Blank
110
2.5" SSD Drive Installation
111
Figure 144. Attaching the Drive Blank to 7 MM SSD
111
Figure 145. 2.5" 7 MM Drive Outside Chassis, Ready for Installation
111
Figure 146. 2.5" 7 MM Drive Installation into Chassis
111
Figure 147. 2.5" 15 MM Drive Outside Chassis, Ready for Installation
112
Figure 148. 2.5" 15 MM Drive Installation into Chassis
112
3.5" Drive Carrier Removal
113
3.5" HDD Drive Assembly
113
Figure 149. 3.5" Drive Removal
113
Figure 150. 3.5" Drive Assembly - Drive Blank / Drive Removal
113
Assembly of 2.5" SSD Drive into a 3.5" Drive Carrier
114
Figure 151. 3.5" Drive Assembly - Drive Installation to Carrier
114
Figure 152. 3.5" Drive Carrier to 2.5" SSD Bracket - Tab Removal and Mount SSD to Bracket
114
Figure 153. 3.5" Drive Carrier to 2.5" SSD Bracket - Mount Bracket Assembly to Carrier
115
Figure 154. 3.5" Drive Carrier to 2.5" SSD Bracket - Secure SSD to Carrier
115
3.5" Drive Carrier Installation
116
Figure 155. 3.5" Drive Assembly Installation
116
Backplane Replacement
117
X 2.5" Backplane
117
Figure 156. 8 X 2.5" Backplane Removal
117
Figure 157. 8 X 2.5" Backplane Installation
118
12 X 3.5" Backplane Installation
119
Figure 158. 12 X 3.5" Backplane Removal
119
X 2.5" Backplane and 12 X 3.5" Backplane Cabling
120
Figure 159. 12 X 3.5" Backplane Installation
120
6.10 System Battery Replacement
121
Figure 160. Replacing the System Battery
121
6.11 Server Board Replacement
122
Figure 161. Server Board Removal
122
Figure 162. Server Board Installation
123
Appendix A. Getting Help
124
Appendix B. Internal Cable Routing Channels
125
Figure 163. System Cable Routing Channels
125
Appendix C. General Memory Population Rules
126
DDR4 DIMM Population Rules
126
Figure 164. Intel® Server System M50CYP2UR Family Memory Slot Layout
126
Intel® Optane™ DC Persistent Memory 200 Series Module Rules
127
Table 5. Intel® Optane™ DC Persistent Memory 200 Series Module Support Guidelines
128
Table 6. Standard DRAM Dimms Compatible with Intel® Optane™ Persistent Memory 200 Series Module
128
Appendix D. System Status LED Operating States and Definition
129
Table 7. System Status LED State Definitions
129
Appendix E. POST Code Diagnostic LED Decoder
131
Figure 165. Onboard POST Diagnostic Leds
131
Early POST Memory Initialization MRC Diagnostic Codes
132
Table 8. POST Progress Code LED Example
132
Table 9. MRC Progress Codes
132
Table 10. MRC Fatal Error Codes
133
BIOS POST Progress Codes
134
Table 11. POST Progress Codes
134
Appendix F. POST Error Codes
137
Table 12. POST Error Messages and Handling
138
POST Error Beep Codes
143
Table 13. POST Error Beep Codes
143
Table 14. Integrated BMC Beep Codes
143
Processor Initialization Error Summary
144
Table 15. Mixed Processor Configurations Error Summary
144
Appendix G. System Packaging Assembly Instructions
146
Appendix H. Safety Instructions
149
Appendix I. Glossary
161
Advertisement
Advertisement
Related Products
Intel M50CYP1UR Series
Intel M50FCP1UR
Intel M50FCP2UR
Intel MFSYS25V2
Intel MFSYS25 - AXXPSU 1000W Power Supply Module
Intel MFSYS35
Intel MFS5520VIBR
Intel MFS5520VIR
Intel MFS2600K
Intel MB440LX
Intel Categories
Motherboard
Computer Hardware
Server
Desktop
Server Board
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL