Summary of Contents for Intel SR1530AHNA

  • Page 1 ® Intel Server Chassis SR1530 ® Intel Server System SR1530AH Technical Product Specification Intel order number D77400-002 Revision 1.0 November 2006 Enterprise Platforms and Services Division - Marketing...
  • Page 2: Revision History

    Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
  • Page 3: Table Of Contents

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Table of Contents Table of Contents 1. Introduction .......................... 1 Chassis Views ......................1 Chassis Dimensions ....................1 System Components ....................2 System Boards ......................3 ® 1.4.1 Intel Server System SR1530AHLX ................ 3 ®...
  • Page 4 Table of Contents Intel® Server Chassis SR1530 Intel® Server System SR1530AH 2.12.1 AC Line 5VSB Holdup ................... 15 2.13 Power Recovery ....................15 2.13.1 Voltage Brown Out....................15 2.13.2 Voltage Interruptions....................15 2.14 AC Line Inrush ....................... 15 2.15 AC Line Isolation Requirements ................16 2.16...
  • Page 5 Intel® Server Chassis SR1530 Intel® Server System SR1530AH Table of Contents 2.39.2 Humidity......................... 26 2.39.3 Altitude........................26 2.39.4 Mechanical Shock....................27 2.39.5 Random Vibration ....................27 2.39.6 Thermal Shock (Shipping) ..................27 2.39.7 Ecological Requirements ..................27 2.39.8 Catastrophic Failure....................27 3.
  • Page 6 Table of Contents Intel® Server Chassis SR1530 Intel® Server System SR1530AH 8.3.7 RRL (Korea)......................43 8.3.8 CNCA (CCC-China) ....................43 Replacing the Back up Battery ................44 Serviceability and Availability................. 45 Restriction of Hazardous Substances (RoHS) Compliance........45 Regulated Specified Components ................. 46 Appendix A: Integration and Usage Tips...................
  • Page 7 Intel® Server Chassis SR1530 Intel® Server System SR1530AH List of Figures List of Figures Figure 1. Intel® Server System SR1530AH.................. 1 Figure 2. Major System Components ................... 2 Figure 3. Back Panel Features ..................... 3 Figure 4. Drive Bays ........................4 Figure 5.
  • Page 8 List of Tables Intel® Server Chassis SR1530 Intel® Server System SR1530AH List of Tables Table 1. Chassis Dimensions ....................... 1 Table 2. Acoustic Requirements ....................9 Table 3. Environmental Requirements..................9 Table 4. Cable Lengths......................... 9 Table 5. P1 Main Power Connector ................... 10 Table 6.
  • Page 9 Intel® Server Chassis SR1530 Intel® Server System SR1530AH List of Tables Table 32. Diagnostic LED POST Code Decoder ................. III Table 33. POST Error Beep Codes .....................VI Revision 1.0 Intel order number D77400-002...
  • Page 11: Introduction

    ® The Intel Server Chassis SR1530 is a 1U server chassis that is designed to support the Intel Server Boards S3000AH and S3000AHLX. The server boards and the chassis have features that are designed to support the high-density server market. This chapter provides a high-level overview of the chassis features.
  • Page 12: System Components

    Introduction Intel® Server Chassis SR1530 Intel® Server System SR1530AH System Components AF000970 Rack handles (two) System Memory DIMM Sockets PCI cooling fan System blower fans (two) Processor air duct Hard drives Brackets (two) PCI add-in card bracket Control panel Processor and Heat Sink...
  • Page 13: System Boards

    Intel Server System SR1530AHLX ® ® The Intel Server System SR1530AHLX includes an Intel Server Board S3000AHLX. This board supports two different riser card options: • PCI-X* – capable of supporting a single full height/full length PCI-X* 66/100 MHz add-in card.
  • Page 14: Intel Server System Sr1530Ah

    Intel Server System SR1530AH ® ® The Intel Server System SR1530AH includes an Intel Server Board S3000AH. This board supports a PCI Express* riser card. • PCI Express* – capable of supporting a single full height/full length x8 PCI Express* add-in card.
  • Page 15: System Cooling

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Introduction System Cooling The chassis provides two non-redundant blower fans and one PCI cooling fan. When external ambient temperatures remain within specified limits, the cooling system will provide sufficient air flow for all drive configurations, processors, supported memory, and add-in cards.
  • Page 16: Power Sub-System

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System The power sub-system of the server chassis consists of a single non-redundant 350 W power supply with 7 outputs; 3.3V, 5V, 12V1, 12V2, 12V3, -12V and 5VSB. The form factor fits into a 1U system and provides a wire harness output to the system.
  • Page 17: Mechanical Specifications

    Power Sub-System Mechanical Specifications ® The 1U 350 W power supply is designed specifically for use in the Intel Server Chassis SR1530. The physical size of the power supply enclosure is intended to accommodate power ranges from 350 W. The power supply size is 40mm x 106mm x 300mm and has a wire harness for the DC outputs.
  • Page 18: Airflow Requirements

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH Airflow Requirements The power supply shall incorporate two 40mm fans for self-cooling and system cooling. The fans will provide no less than 8 CFM airflow through the power supply when installed in the system.
  • Page 19: Temperature

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System Table 2. Acoustic Requirements Operating Conditions Inlet Temperature % of Maximum Loading LwAd (BA) Condition Condition Maximum 45ºC 100% Operating 28°C Idle 28°C Standby (main outputs off) 5Vsb/2A < 5.4 28°C...
  • Page 20: P1 Main Power Connector

    P1 add cable bend requirement at P1. 2.5.2 P2 Processor Power Connector Connector housing: 8-Pin Molex* 39-01-2085 or equivalent. Contact: Molex 44476-1111 or Molex 5556 as the alternative, or equivalent approved by Intel. Table 6. P2 Processor Power Connector Signal 18 AWG color...
  • Page 21: Hd Power Connector (P3)

    +5Vsb Purple 2.5.4 Slimline Power Connector (P4) Connector housing: 4-pin Molex* 39-01-3042 or equivalent. Contact: Molex 44476-1111 or Molex 5556 as the alternative, or equivalent approved by Intel. Table 8. Slim-line Power Connector SIGNAL 18 AWG COLOR SIGNAL 18 AWG COLOR...
  • Page 22: Ac Power Cord Specification Requirements

    The power supply module marking supports the following requirements: safety agency requirements, government requirements (if required, e.g. point of manufacturing), power supply vendor requirements, and Intel manufacturing and field support requirements. AC Input Voltage The power supply must operate within all specified limits over the following input voltage range, shown in table below.
  • Page 23: Ac Line Transient Specification

    The power supply meets the following electrical immunity requirements when connected to a cage with an external EMI filter which meets the criteria defined in the SSI document EPS Power Supply Specification. For further information on Intel standards please request a copy of the Intel Environmental Standards Handbook.
  • Page 24: Electrostatic Discharge Susceptibility

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH 2.10.1 Electrostatic Discharge Susceptibility The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4- 2:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
  • Page 25: Ac Line Dropout / Holdup

    11:1995 test standard and performance criteria C defined in Annex B of CISPR 24. In addition the power supply shall meet the following Intel requirements: A continuous input voltage below the nominal input range shall not damage the power supply or cause overstress to any power supply component.
  • Page 26: Ac Line Isolation Requirements

    The power supply shall meet all safety agency requirements for dielectric strength. Additionally, the power supply vendor must provide Intel with written confirmation of the dielectric withstand test which includes: voltage level, duration of test and identification detailing how each power supply is marked to indicate the dielectric withstand test had been completed successfully.
  • Page 27: Grounding

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System 2.20 Grounding The output ground of the pins of the power supply provides the output power return path. The output connector ground pins shall be connected to the safety ground (power supply enclosure).
  • Page 28: Voltage Regulation

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH 2.23 Voltage Regulation The power supply output voltages must stay within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
  • Page 29: Capacitive Loading

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System 2.24 Capacitive Loading The power supply shall be stable and meet all requirements with the following capacitive loading ranges. Table 17. Capacitve Loading Conditions Output Units +3.3V 2200 μF μF...
  • Page 30: Soft Starting

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH 2.28 Soft Starting The power supply shall contain a control circuit which provides a monotonic soft start for its outputs without overstress of the AC line or any power supply components at any specified AC line or load conditions.
  • Page 31: Figure 7. Output Voltage Timing

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System Vout Vout vout_off vout rise vout_on Figure 7. Output Voltage Timing Revision 1.0 Intel order number D77400-002...
  • Page 32: Figure 8. Turn On/Off Timing (Power Supply Signals)

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH Table 20. Turn On/Off Timing Item Description UNITS Delay from AC being applied to 5VSB being within regulation. 1500 sb_on_delay Delay from AC being applied to all output voltages being within...
  • Page 33: Residual Voltage Immunity In Standby Mode

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System 2.31 Residual Voltage Immunity in Standby mode The power supply should be immune to any residual voltage placed on its outputs (typically a leakage voltage through the system from standby output) up to 500 mV. There shall be no additional heat generated, nor stress of any internal components with this voltage applied to any individual output, and all outputs simultaneously.
  • Page 34: Over-Temperature Protection (Otp)

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH Table 22. Over-Voltage Protection (OVP) Limits Output Voltage MIN (V) MAX (V) +3.3V +12V 13.3 14.5 -12V -13.3 +5VSB 2.35 Over-Temperature Protection (OTP) The power supply will be protected against over-temperature conditions caused by loss of fan cooling or excessive ambient temperature.
  • Page 35: Figure 9. Pson# Required Signal Characteristic

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System Table 23. PSON Signal Characteristic Signal Type Accepts an open collector/drain input from the system. Pull-up to VSB located in power supply. PSON = Low PSON = High or Open Logic level low (power supply ON) 1.0V...
  • Page 36: Pwok (Power Ok) Output Signal

    Power Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH 2.38 PWOK (Power OK) Output Signal PWOK is a power OK signal and will be pulled HIGH by the power supply to indicate that all the outputs are within the regulation limits of the power supply. When any output voltage falls below regulation limits or when AC power has been removed for a time sufficiently long so that power supply operation is no longer guaranteed, PWOK will be de-asserted to a LOW state.
  • Page 37: Mechanical Shock

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Power Sub-System 2.39.4 Mechanical Shock Non-operating: 50 G Trapezoidal Wave, Velocity change = 170 in. / sec. Three drops in each of six directions are applied to each of the samples. 2.39.5...
  • Page 38: Cooling Sub-System

    Cooling Sub-System Intel® Server Chassis SR1530 Intel® Server System SR1530AH Cooling Sub-System The cooling sub-system consists of two 97 x 94 x 33 blower fan and one 40 x 40 x 15 PCI cooling fan and a CPU air duct. These components are used to provide the necessary cooling and airflow to the system.
  • Page 39: Power Supply Fans

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Cooling Sub-System Table 25. Cooling Zones Cooling Greatest Cooling Influence Zone System Fan Blower #1 CPU/MCH Primary cooling for the CPU and the system memory and #2 PCI Cooling Fan Primary cooling for HDD0, full-height PCI cards, PXH...
  • Page 40: Peripheral And Hard Drive Support

    Peripheral and Hard Drive Support Intel® Server Chassis SR1530 Intel® Server System SR1530AH Peripheral and Hard Drive Support The server chassis provides support for two fixed hard drive bays and one slimline peripheral drive bay at the front of the chassis. The fixed hard drive bays are designed to support SATA drives.
  • Page 41: Optical Drive Support

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Peripheral and Hard Drive Support 4.1.1 Optical Drive Support The chassis supports a slimline IDE optical drive. The drive is mounted with two side mount rail accessories and is connected to an interposer card attached to the drive. The drive assembly is then installed in to the slimline drive bay.
  • Page 42: System Fan Connectors

    Peripheral and Hard Drive Support Intel® Server Chassis SR1530 Intel® Server System SR1530AH 4.2.1 System Fan Connectors The system supports two system fan blowers and one PCI cooling fan. The pin-out for each connector is provided in the following table.
  • Page 43: Front Control Panel

    The control panel assembly module slides into a predefined slot on the front of the chassis. Once installed, communication to the server board can be achieved through a standard 24-pin cable connected directly to the server board. ® Note: The status LED is not used on the Intel Server System SR1530AH. AF001000 Item...
  • Page 44: Power / Sleep Led

    Blink Sleep / ACPI S1 state (on standby power) Power Off / ACPI S4 state System Status Status LED is not used on the Intel® Server Systems SR1530AH and SR1530AHLX (on standby power) Green Random blink HDD access Disk Activity...
  • Page 45: Pci Riser Cards And Assembly

    ® PCIe* x8 full-height adapter card. The Intel Server Board S3000AHLX supports either a PCI ® Express x8 or a PCI-X* riser card inserted into the Intel Adaptive Slot. AF000676 Figure 14. PCI Riser Card Assembly Figure 15. 1U PCIX Riser Card Mechanical Drawing Revision 1.0...
  • Page 46: Figure 16. 1U Pcie Riser Card Mechanical Drawing

    PCI Riser Cards and Assembly Intel® Server Chassis SR1530 Intel® Server System SR1530AH Figure 16. 1U PCIE Riser Card Mechanical Drawing Intel order number D77400-002 Revision 1.0...
  • Page 47: Supported Intel Server Boards

    Supported Intel® Server Boards ® Supported Intel Server Boards ® The chassis is mechanically and functionally designed to support the Intel Server Boards ® S3000AH and S3000AHLX. See the Intel Server Board S3000AH Technical Product Specification for detailed server board information.
  • Page 48: Environmental And Regulatory Specifications

    Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random Shock, operating Half sine, 2 g peak, 11 mSec +/-15kV except I/O port +/-8KV per Intel Environmental test specification System Cooling 2550 BTU/hour Requirement in BTU/Hr Product Regulatory Compliance 8.2.1...
  • Page 49: Product Emc Compliance

    The platform has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed a compatible Intel host system. For information on compatible host system(s) refer to Intel’s Server Builder website or contact your local Intel representative.
  • Page 50: Product Regulatory Compliance Markings

    Environmental and Regulatory Specifications Intel® Server Chassis SR1530 Intel® Server System SR1530AH 8.2.4 Product Regulatory Compliance Markings ® The Intel Server Chassis SR1530 is provided with the following regulatory marks. Regulatory Compliance Region Marking cULus Listing Marks USA/Canada GS Mark...
  • Page 51: Electromagnetic Compatibility Notices

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Environmental and Regulatory Specifications Electromagnetic Compatibility Notices 8.3.1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 52: Ices-003 (Canada)

    Environmental and Regulatory Specifications Intel® Server Chassis SR1530 Intel® Server System SR1530AH This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 53: Rrl (Korea)

    English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
  • Page 54: Replacing The Back Up Battery

    Environmental and Regulatory Specifications Intel® Server Chassis SR1530 Intel® Server System SR1530AH Replacing the Back up Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong.
  • Page 55: Serviceability And Availability

    15 min Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
  • Page 56: Regulated Specified Components

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder. If you do not have access to Intel’s Web address, please contact your local Intel representative. • Server chassis (base chassis is provided with power supply and fans)⎯UL listed.
  • Page 57 Intel® Server Chassis SR1530 Intel® Server System SR1530AH Environmental and Regulatory Specifications This page intentionally left blank Revision 1.0 Intel order number D77400-002...
  • Page 59: Appendix A: Integration And Usage Tips

    Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips ® This section provides a list of useful information that is unique to the Intel Server Chassis ® SR1530 and should be kept in mind while integrating and configuring your Intel Server Board S3000AH or S3000AHLX.
  • Page 60: Appendix B: Post Code Diagnostic Led Decoder

    ACh. Note: The following example is for illustrative purposes only; the diagram does not match the ® back edge of the server board in the Intel Server Systems SR1530AH and SR1530AHLX. Table 31. POST Progress Code LED Example...
  • Page 61 Intel® Server Chassis SR1530 Intel® Server System SR1530AH Appendix B: POST Code Diagnostic LED Decoder Table 32. Diagnostic LED POST Code Decoder Diagnostic LED Decoder Description Checkpoint G=Green, R=Red, A=Amber Host Processor 0x10h Power-on initialization of the host processor (bootstrap processor)
  • Page 62 Appendix B: POST Code Diagnostic LED Decoder Intel® Server Chassis SR1530 Intel® Server System SR1530AH Diagnostic LED Decoder Description Checkpoint G=Green, R=Red, A=Amber 0x78h Resetting the console controller 0x79h Disabling the console controller 0x7Ah Enabling the console controller Keyboard (PS2 or USB)
  • Page 63 Intel® Server Chassis SR1530 Intel® Server System SR1530AH Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder Description Checkpoint G=Green, R=Red, A=Amber Pre-EFI Initialization (PEI) Core 0xE0h Started dispatching early initialization modules (PEIM) 0xE2h Initial memory found, configured, and installed correctly...
  • Page 64: Appendix C: Post Error Beep Codes

    Appendix C: POST Error Beep Codes Intel® Server Chassis SR1530 Intel® Server System SR1530AH Appendix C: POST Error Beep Codes The following table lists POST error beep codes. Prior to system video initialization, BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user visible code on POST Progress LEDs.
  • Page 65: Glossary

    Intel® Server Chassis SR1530 Intel® Server System SR1530AH Glossary Glossary Word / Acronym Definition Australian Communication Authority ANSI American National Standards Institute Baseboard Management Controller CMOS Complementary Metal Oxide Silicon DC-to-DC Emergency Management Port Front Panel Fault Resilient Boot Field Replaceable Unit...
  • Page 66: Reference Documents

    Server Chassis SR1530 AC Power Supply Module Specification ® • Intel Server Board S3000AH/S3000AHLX Tested Hardware and OS List ® ® • Intel Server Board S3000AH/S3000AHLX / Intel Server System SR1530AH/SR1530AHLX Spares/Parts List and Configuration Guide VIII Intel order number D77400-002 Revision 1.0...